Series AM150HB-NZ
150 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
%
Voltage accuracy
±1
±3
Over voltage protection
Over load protection
Short Circuit protection
Thermal shutdown
110~140
% of Vout
% of Iout
Hiccup
110~180
Hiccup, Continuous, Auto-recovery
100
On Case
Full load
120
±0.3
±0.5
±0.03
ºC
% of Vin
%
Line voltage regulation
Load voltage regulation
Temperature coefficient
10% to 100% Full Load
Full load
%/oC
20MHz Bandwidth (with 10% to100%
Full load)
Ripple & Noise*
60
±3
150
±5
mV p-p
25% load step change, 15V/24V
Output Voltage
% of Max
Transient Response Deviation
25% load step change, 12V Output
Voltage
±4
±8
% of Max
Transient Recovery
300
500
µsec
%
Voltage adjustment range(Trim)
95 to 110
Output voltage remote
compensation(Sense)
105
% of Vout
NOTE: * The measuring method of ripple and noise, please refer to Fig. 2.
General Specifications
Parameters
Conditions
PWM mode
Typical
Maximum
Units
KHz
oC
oC
oC
Switching frequency
160
Operating temperature
Storage temperature
Maximum case temperature
Cooling
With derating (see graph below)
-40 to +100
-55 to +125
-40 to +100
Within the operating temperature curve
Free Air Convection or Forced Convection 200-1000 LFM airflow
5 to 95
Humidity
% RH
Aluminum plate + plastic case
Heatsink
Non-conductive Black Plastic (UL94V-0 rated)
Case material
Aluminum Alloy
Weight
70
g
Weight (with Heatsink)
Dimensions (L x W x H)
Dimensions (L x W x H) with Heatsink
MTBF
120
g
57.9 x 61.0 x 12.7 mm
2.28 x 2.40 x 0.5 inches
2.28 x 2.44 x 1.21 inches
>500,000 hrs (MIL-HDBK-217 F at Plate Tb=+70℃, GB oC)
57.9 x 62.0 x 30.8 mm
Maximum soldering temperature
1.5mm from case for 10 sec 300
oC
Safety Specifications
Parameters
EMI - Conducted and radiated emission
CISPR22/EN55022, class B (with the recommended EMC circuit), see figure 4.
IEC 61000-4-2, Criteria B
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
IEC 61000-4-3, Criteria A
Standards
IEC 61000-4-4, Criteria B (with the recommended EMC circuit), see figure 4.
IEC 61000-4-5, Criteria B (with the recommended EMC circuit), see figure 4.
IEC 61000-4-6, 10Vr.m.s, Criteria A
RF, Conducted Disturbance Immunity
Immunity of Short interruption
EN50155, 100%-0%, 10ms, Criteria B
www.aimtec.com
F 051e R1
Tel: +1 514 620 2722
2 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only