Series AM150HB-NZ  
150 Watt | DC-DC Converter  
Trimming  
Output voltage can be externally trimmed by utilizing the methods as shown below  
Fixed Resistor  
Variable Potentiometer  
Leave open if not used.  
AM150HB-11012S-NZ  
Trim down %  
Vout (VDC)  
1
2
3
4
5
11.4  
6
7
8
9
10  
10.8  
11.88  
11.76  
11.64  
11.52  
11.28  
11.16  
11.04  
10.92  
Rt down (KΩ) 493.292 298.652 209.727 158.785 125.773 102.642 85.532 72.364 61.916 53.423  
Trim up %  
Vout (VDC)  
Rt up (KΩ)  
1
2
3
4
5
12.6  
6
7
8
9
13.08  
9.752  
10  
13.2  
6.795  
12.12  
12.24  
12.36  
12.48  
12.72  
12.84  
12.96  
703.635 156.120 81.079 51.275 35.277 25.295 18.474 13.517  
AM150HB-11015S-NZ  
Trim down %  
Vout (VDC)  
1
2
14.7  
3
4
14.4  
5
6
14.1  
7
8
13.8  
9
10  
13.5  
14.85  
14.55  
14.25  
13.95  
13.65  
Rt down (KΩ) 638.028 398.954 285.279 218.840 175.260 144.474 121.568 103.860 89.761 78.271  
Trim up %  
Vout (VDC)  
Rt up (KΩ)  
1
2
15.3  
3
4
15.6  
5
6
15.9  
7
8
16.2  
9
16.35  
9.498  
10  
16.5  
6.287  
15.15  
15.45  
15.75  
16.05  
1271.500 183.455 90.426 55.777 37.679 26.559 19.034 13.602  
AM150HB-11024S-NZ  
Trim down %  
Vout (VDC)  
1
2
3
4
5
22.8  
6
7
8
9
10  
21.6  
23.76  
23.52  
23.28  
23.04  
22.56  
22.32  
22.08  
21.84  
Rt down (KΩ) 1289.521 792.049 564.771 434.571 350.197 291.076 247.346 213.690 186.986 165.281  
Trim up %  
Vout (VDC)  
Rt up (KΩ)  
1
2
3
4
5
25.2  
6
7
8
9
10  
26.4  
7.803  
24.24  
24.48  
24.72  
24.96  
25.44  
25.68  
25.92  
26.16  
795.550 176.609 91.778 58.086 40.001 28.717 21.006 15.402 11.146  
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled  
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the  
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,  
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components  
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This  
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate  
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.  
www.aimtec.com  
F 051e R1  
Tel: +1 514 620 2722  
6 of 6  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only