Series AM10E-Z
10 Watt | DC-DC Converter
Output Specifications (continued)
Parameters
Short circuit restart
Conditions
Typical
Auto Recovery
Maximum
Units
Over load protection
140
±0.5
±0.5
±0.5
±1.0
±0.02
100
%
%
%
%
%
%
mVp-p
ms
Line voltage regulation (Single)
Line voltage regulation (Dual)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
HL-LL
HL-LL
10-100%
10-100%
oC
20MHz Bandwidth
Rising time
10
General Specifications
Parameters
Switching frequency
Conditions
100% load
-5Vin
Typical
200
Maximum
Units
KHz
oC
oC
oC
-40 to +65
-40 to +85
Operating temperature
12, 24, 48 Vin
Storage temperature
Maximum case temperature
-40 to +125
100
5Vin
12, 24, 48 Vin
See Graph
Not Required
Derating
Cooling
Free air convection
Humidity
95
%
Case material
Potting Material
Weight
Nickel coated copper
UL94V-0 rated
30
g
Dimensions (L x W x H)
Tolerance ±0.5mm
2.00 x 1.00 x 0.40 inches
50.80 x 25.40 x 10.16 mm
5Vin: 1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
MTBF
12, 24, 48 Vin: > 1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
1.5mm from case max 10 sec
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
260
oC
uS
%
250
±3
Safety Specifications for models with 12, 24, and 48 Vin
Parameters
Agency approvals
CE
EN 55022 (Radiated) – Class A
EN 55024 – Class A
IEC61000-4-2
Standards
IEC61000-4-3
NOTE: Meets IEC60950-1:2001
Pin Out Specifications
Pin
1
2
Single
+V Input
-V Input
Dual
+V Input
-V Input
3
4
5
+V Output
No Pin.
-V Output
+V Output
Common.
-V Output
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only