AIC1722A
ꢀ ELECTRICAL CHARACTERISTICS (TA=25°C, CIN=1µF, COUT=1µF, unless oth-
erwise specified.) (Note 1)
PARAMETER
TEST CONDITIONS
MIN.
TYP.
MAX.
UNIT
No Load
AIC1722A-52
AIC1722A-50
AIC1722A-38
AIC1722A-37
AIC1722A-35
AIC1722A-33
AIC1722A-30
AIC1722A-27
AIC1722A-25
AIC1722A-20
AIC1722A-18
Output Voltage
V =8V
IN
-2
+2
%
I =1mA,
L
Line Regulation
1.4V≤V
3.3V≤V
≤3.2V
OUT
≤5.2V
OUT
V =4V~8V
V =5.5V~8V
IN
3
3
10
15
mV
IN
I =0.1~300mA
L
Load Regulation
(Note 2)
V =5V
V =7V
IN
IN
1.4V≤V
4.0V≤V
≤3.9V
≤5.2V
7
15
20
40
mV
mA
OUT
OUT
Current Limit
(Note 3)
V =7V, V
=0V
OUT
300
IN
4.0V≤V
≤5.2V
400
470
570
800
1260
OUT
OUT
OUT
OUT
OUT
3.0V≤V
2.5V≤V
2.0V≤V
1.4V≤V
≤3.9V
≤2.9V
≤2.4V
≤1.9V
Dropout Voltage
(Note 4)
I =300mA
L
mV
IO=0.1mA~I
1.4V≤VOUT≤3.9V
4.0V≤VOUT≤5.2V
MAX
Ground Current
V =5~8V
V =7~8V
IN
55
55
80
80
IN
µA
Note 1:
Specifications are production tested at TA =25°C. Specifications over the -40°C to 85°C operating
temperature range are assured by design, characterization and correlation with Statistical Quality
Controls (SQC).
Note 2:
Note 3:
Note 4:
Regulation is measured at constant junction temperature, using pulse testing with a low ON time.
Current limit is measured by pulsing a short time.
Dropout voltage is defined as the input to output differential at which the output voltage drops
100mV below the value measured with a 1V differential.
4