AIC1550  
ELECTRICAL CHARACTERISTICS  
(VIN=+3.6V, TA=+25°C, SYNC/MODE =GND, SHDN =IN, unless otherwise specified.) (Note1)  
PARAMETER  
SYMBOL CONDITIONS  
MIN  
2.5  
TYP  
MAX UNITS  
Input Voltage Range  
Output Adjustment Range  
VIN  
6.5  
VIN  
V
V
VOUT  
VREF  
Feedback Voltage  
VFB  
0.735 0.75 0.765  
+1  
V
Line Regulation  
Load Regulation  
Duty Cycle = 100% to 23%  
OUT = 0 to 800mA  
%
I
-1.3  
%
FB Input Current  
IFB  
VFB = 1.4V,  
-50  
0.01  
50  
nA  
VIN = 3.6V  
VIN = 2.5V  
VIN = 3.6V  
VIN = 2.5V  
0.32  
0.38  
0.32  
0.38  
0.65  
P-Channel On-Resistance PRDS(ON) ILX = 100mA  
N-Channel On-Resistance NRDS(ON) ILX = 100mA  
0.65  
P-Channel Current-Limit  
(Note 2)  
1
1.5  
35  
2.1  
70  
1
A
Threshold  
SYNC/MODE = GND,  
Quiescent Current  
µA  
µA  
VFB = 1.4V, LX unconnected  
SHDN = LX = GND, includes LX  
leakage current  
Shutdown Supply Current  
0.1  
LX Leakage Current  
Oscillator Frequency  
SYNC Capture Range  
Maximum Duty Cycle  
Undervoltage Lockout  
Threshold  
VIN = 5.5V, VLX = 0 or 5.5V  
-20  
400  
500  
100  
0.1  
20  
µA  
KHz  
KHz  
%
fOSC  
500  
600  
1000  
dutyMAX  
UVLO  
VIN rising, typical hysteresis is  
85mV  
1.9  
2
2.0  
0.1  
2.1  
V
Logic Input High  
VIH  
VIL  
SHDN , SYNC/MODE, LIM  
SHDN , SYNC/MODE, LIM  
SHDN , SYNC/MODE, LIM  
V
V
Logic Input Low  
0.4  
1
Logic Input Current  
SYNC/MODE Minimum  
Pulse Width  
-1  
µA  
High or low  
500  
nS  
Note 1: Specifications are production tested at TA=25°C. Specifications over the -40°C to 85°C operating  
temperature range are assured by design, characterization and correlation with Statistical  
Quality Controls (SQC).  
Note 2: Maximum specification is guaranteed by design, not production tested.  