Absolute Maximum Ratings
Absolute maximum limits mean that no catastrophic damage will occur if the product is subjected to these ratings for short periods, provided
each limiting parameter is in isolation and all other parameters have values within the performance specification. It should not be assumed that
limiting values of more than one parameter can be applied to the product at the same time.
Parameter
Laser Forward Current
Laser Reverse Current
Laser Reverse Voltage
Photodiode Reverse Voltage
Photodiode Forward Current
Operating Temperature
Storage Temperature
Relative Humidity
Fiber Pull Strength
Mechanical Shock
Vibration
Symbol
If
Ir
Vlr
Vr
Ipf
Tc
Ts
RH
Conditions
DC
DC
DC
DC
DC
Pf min.
Limits
Min.
Max.
-
150
-
100
-
2
-
10
-
1
-40
+85
-40
+85
0.0
non-
condensing
-
10
Units
mA
µA
V
V
mA
°C
°C
%RH
N
Mil Std 883D, Method 2002,
Condition B
Mil Std 883D, Method 2007,
Condition A
Performance Specifications
Parameter
LASER
Threshold Current
Peak Optical
Output Power
Optical Output
Power
Slope Efficiency
Forward Voltage
Differential
Resistance
Centre Wavelength
Ic Change with
Temperature
Linewidth
Rise Time
Fall Time
Small Signal
Freq. Response
Symbol
Conditions
CW, Tc = 25°C, Pf = Pf min.
unless otherwise stated
LSC3300
Min. Max.
LSC3100
Min. Max.
Units
Ith
Pf
Pth
η
Vf
Rd
λc
∆λ/∆T
∆λ
τr
τf
Bw
Pth = Pf @ Ith -2 mA
5
100
-
4
-
-
1280
-
-
-
-
1.0
35
-
10
16
1.8
10
1330
0.5
5
0.5
0.5
-
5
1000
-
40
-
-
1280
-
-
-
-
1.0
35
-
50
100
1.8
10
1330
0.5
5
0.5
0.5
-
mA
µW
µW
µW/mA
V
Ω
nm
nm/°C
nm
ns
ns
GHz
dV/dI
Note 1
Tc = -40°C to 85°C
FWHM (2.35s)
10% to 90%: Ith to Pf = Pf min.
90% to 10%: Pf = Pf min. to Ith
Pf = Pf min.,
±
3 dB
Note:
1. Modulated measurement available.
If the specific performance you require is not met by the above parameters, please contact Hewlett-Packard as the submodule