HPMD-7905 Electrical Specifications, ZO = 50Ω, TC[1] as indicated
+25°C[1,3]
+85°C[1,2,3]
–30°C[1,2,3]
Symbol
Parameters
Units
Min Typ
Max
Min Max
Min Max
fRX
Receive Bandwidth
MHz
dB
1930.6
48
—
—
1989.4
—
1930.6 1989.4
1930.6 1989.4
S23 Rx
Attenuation in Transmit Band
(1850.6–1853 MHz)
47
47
—
—
—
—
—
3.5
3.8
3.8
45
47
—
—
—
—
—
4.5
3.8
3.5
S23 Rx
S23 Rx
S23 Rx
S23 Rx
Attenuation in Transmit Band
(1853–1909.4 MHz)
dB
dB
dB
dB
50
—
—
—
54
—
3.5
3.5
3.5
Insertion Loss in Receive Band
(1930.6–1935 MHz)
—
3.0
—
Insertion Loss in Receive Band
(1935–1987 MHz)
Insertion Loss in Receive Band
(1987–1989.4 MHZ)
∆ S23
S22 Rx
fTX
Ripple in Receive Band
Return Loss in Receive Band
Transmit Bandwidth
dB
—
1.5
—
—
—
—
—
—
—
—
—
—
dB
8.0
—
8.0
8.0
MHz
dB
1850.6
39
1909.4
—
1850.6 1909.4
1850.6 1909.4
S31 Tx
Attenuation in Receive Band
(1930.6–1931 MHz)
37.5
37.5
37.5
35
—
—
—
—
3.8
3.5
3.8
32.5
—
—
—
—
3.8
3.5
3.0
S31 Tx
S31 Tx
S31 Tx
S31 Tx
S31 Tx
S31 Tx
Attenuation in Receive Band
(1931–1934 MHz)
dB
dB
dB
dB
dB
dB
39
—
42
—
—
—
3.0
3.0
3.0
35
Attenuation in Receive Band
(1934–1987 MHz)
39
37.5
37.5
—
Attenuation in Receive Band
(1987–1989.4 MHz)
37.5
—
—
—
—
2.5
2.5
—
Insertion Loss in Transmit Band
(1850.6–1853 MHz)
—
Insertion Loss in Transmit Band
(1853–1907 MHz)
—
—
Insertion Loss in Transmit Band
(1907–1909.4 MHz)
—
—
∆ S31
S11 Tx
IP3
Ripple in Transmit Band
dB
dB
dBm
dB
dB
dB
dB
dB
dB
dB
—
8.0
—
49
50
50
39
39
39
37
2.0
—
>60
—
54
—
—
—
—
—
—
—
—
—
—
—
8.0
—
47
48
45
38
38
37
35
—
—
—
—
—
—
—
—
—
—
—
8.0
—
47
47
48
35
38
38
37
—
—
—
—
—
—
—
—
—
—
Return Loss in Transmit Band
Third Order Intercept Point
S21
Tx-Rx Isolation (1850.6 –1860 MHz)
Tx-Rx Isolation (1860– 1907 MHz)
Tx-Rx Isolation (1907– 1909.4 MHz)
Tx-Rx Isolation (1930.6– 1934 MHz)
Tx-Rx Isolation (1934 –1972 MHz)
Tx-Rx Isolation (1972– 1975 MHz)
Tx-Rx Isolation (1975– 1989.4 MHz)
S21
S21
54
S21
42
S21
42
S21
42
S21
—
Notes:
1. TC is defined as case temperature, the temperature of the underside of the duplexer where it
makes contact with the circuit board.
Absolute Maximum Ratings[4]
2. Specifications are given at operating temperature limits and room temperature. To estimate
performance at some intermediate temperature, use linear interpolation.
Parameter
Unit Value
Operating temperature[1] °C
-30 to +85
3. Specifications are guaranteed over the given temperature range, with the input power to the Tx
port equal to +30 dBm (or lower) over all Tx frequencies. The application of input power levels in
excess of +30 dBm will not destroy the duplexer, but its performance may exceed the specification
limits given above.
Storage temperature[1]
°C
-30 to +100
4. Operation in excess of any one of these conditions may result in permanent damage to the device.
2