2
Part Numbering System
HLMP - 1 x xx - x x x xx
Mechanical Option
00: Bulk
01: Tape & Reel, Crimped Leads
02: Tape & Reel, Straight Leads
A1: Right Angle Housing, Uneven Leads
A2: Right Angle Housing, Even Leads
Color Bin Options
0: Full Color Bin Distribution
Maximum Iv Bin Options
0: Open (no max. limit)
Others: Please refer to the Iv Bin Table
Minimum Iv Bin Options
Please refer to the Iv Bin Table
Lens Options
20: Untinted or Microtinted, Non-diffused
21: Tinted, Non-diffused
Color Options
3: GaP HER
4: GaP Yellow
5: GaP Green
Package Options
1: T-1 (3 mm)
Absolute Maximum Ratings at T
A
= 25
°
C
Parameter
Peak Forward Current
Average Forward Current
[1]
DC Current
[2]
Power Dissipation
[3]
Reverse Voltage (I
R
= 100
µA)
Transient Forward Current
[4]
(10
µsec
Pulse)
LED Junction Temperature
Operating Temperature Range
Storage Temperature Range
Lead Soldering Temperature
[1.6 mm (0.063 in.) from body]
Red
90
25
30
135
5
500
110
-55 to +100
Yellow
60
20
20
85
5
500
110
-55 to +100
Green
90
25
30
135
5
500
110
-20 to +100
-55 to +100
260°C for 5 seconds
Units
mA
mA
mA
mW
V
mA
°C
°C
Notes:
1. See Figure 5 (Red), 10 (Yellow), or 15 (Green) to establish pulsed operating conditions.
2. For Red and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. For Red and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at
1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED
die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the
Absolute Maximum Ratings.