8
High Performance Green HLMP-2500/2800/2965 Series
Parameter
Luminous Intensity
per Lighting Emitting
Area
[1]
HLMP-
2500/2800/2820
2550/2835/2855/2870
2965
[4]
2885
Peak Wavelength
Dominant Wavelength
[2]
Forward Voltage per LED
Reverse Breakdown Voltage per LED
[5]
Thermal Resistance LED Junction-to-Pin
λ
PEAK
λ
d
V
F
V
R
Rθ
J-PIN
6
Symbol
I
V
Min.
5
11
25
22
Typ.
25
50
50
100
565
572
2.2
15
150
2.6
Max.
Units
mcd
mcd
mcd
mcd
nm
nm
V
V
°C/W/
LED
I
F
= 20 mA
I
R
= 100
µA
Test Conditions
I
F
= 20 mA
Notes:
1. These devices are categorized for luminous intensity. The intensity category is designated by a letter code on the side of the package.
2. The dominant wavelength,
λ
d
, is derived from the CIE chromaticity diagram and is the single wavelength which defines the color of the
device. Yellow and Green devices are categorized for dominant wavelength with the color bin designated by a number code on the side
of the package.
3. This is an HER/Yellow bicolor light bar. HER electrical/optical characteristics are shown in the HER table. Yellow electrical/optical
characteristics are shown in the Yellow table.
4. This is an HER/Green bicolor light bar. HER electrical/optical characteristics are shown in the HER table. Green electrical/optical
characteristics are shown in the Green table.
5. Does not apply to HLMP-2950 or HLMP-2965.