型号: HFBR-5205
PDF下载: 下载PDF文件 查看货源
内容描述: ATM多模光纤收发器用于SONET OC - 3 / SDH STM - 1的低成本1X9封装形式 [ATM Multimode Fiber Transceivers for SONET OC-3/SDH STM-1 in Low Cost 1x9 Package Style]
分类和应用: 光纤异步传输模式ATM
文件页数/大小: 19 页 / 322 K
品牌: AGILENT [ AGILENT TECHNOLOGIES, LTD. ]
 浏览型号HFBR-5205的Datasheet PDF文件第4页浏览型号HFBR-5205的Datasheet PDF文件第5页浏览型号HFBR-5205的Datasheet PDF文件第6页浏览型号HFBR-5205的Datasheet PDF文件第7页浏览型号HFBR-5205的Datasheet PDF文件第9页浏览型号HFBR-5205的Datasheet PDF文件第10页浏览型号HFBR-5205的Datasheet PDF文件第11页浏览型号HFBR-5205的Datasheet PDF文件第12页  
(2X) ø
20.32
.800
1.9 ± 0.1
.075 ± .004
M A
–A–
Ø0.000
20.32
.800
(9X) ø
0.8 ± 0.1
.032 ± .004
M A
Ø0.000
(8X)
2.54
.100
TOP VIEW
Figure 8. Recommended Board Layout Hole Pattern.
Board Layout - Art Work
The Applications Engineering
group is developing Gerber file
art work for a multilayer printed
circuit board layout incorporating
the recommendations above.
Contact your local Hewlett-
Packard sales representative for
details.
Board Layout - Mechanical
For applications interested in
providing a choice of either a
duplex SC or a duplex ST con-
nector interface, while utilizing
the same pinout on the printed
circuit board, the ST port needs
to protrude from the chassis
panel a minimum of 9.53 nm for
sufficient clearance to install the
ST connector.
Please refer to Figure 8a for a
mechanical layout detailing the
114
recommended location of the
duplex SC and duplex ST
transceiver packages in relation
to the chassis panel.
Regulatory Compliance
These transceiver products are
intended to enable commercial
system designers to develop
equipment that complies with the
various international regulations
governing certification of Infor-
mation Technology Equipment.
See the Regulatory Compliance
Table for details. Additional
information is available from your
Hewlett-Packard sales
representative.
Electrostatic Discharge (ESD)
There are two design cases in
which immunity to ESD damage
is important.
The first case is during handling
of the transceiver prior to
mounting it on the circuit board.
It is important to use normal ESD
handling precautions for ESD
sensitive devices. These precau-
tions include using grounded
wrist straps, work benches, and
floor mats in ESD controlled
areas.
The second case to consider is
static discharges to the exterior of
the equipment chassis containing
the transceiver parts. To the
extent that the duplex SC
connector is exposed to the
outside of the equipment chassis
it may be subject to whatever ESD
system level test criteria that the
equipment is intended to meet.