7
Regulatory Information
The HCPL-316J has been approved by the following
organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
UL
Recognized under UL 1577, component recognition
program, File E55361.
CSA
Approved under CSA Component Acceptance Notice #5,
File CA 88324.
IEC/EN/DIN EN 60747-5-2
Insulation Characteristics*
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage
150 Vrms
for rated mains voltage
300 Vrms
for rated mains voltage
600 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b**
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a**
V
IORM
x 1.5 = V
PR
, Type and Sample Test, t
m
= 60 sec,
Partial Discharge < 5 pC
Highest Allowable Overvoltage**
(Transient Overvoltage t
ini
= 10 sec)
Safety-limiting values - maximum values allowed in the event of
a failure, also see Figure 2.
Case Temperature
Input Power
Output Power
Insulation Resistance at T
S
, V
IO
= 500 V
Symbol
Characteristic
I - IV
I - III
I - II
55/100/21
2
891
1670
Unit
V
IORM
V
PR
V
PEAK
V
PEAK
V
PR
1336
V
PEAK
V
IOTM
6000
V
PEAK
T
S
P
S, INPUT
P
S, OUTPUT
R
S
175
400
1200
>10
9
°C
mW
mW
*
Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application. Surface mount classification is class A in accordance with CECCOO802.
** Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations
section IEC/EN/DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
1400
1200
P
S
– POWER – mW
P
S
, OUTPUT
P
S
, INPUT
1000
800
600
400
200
0
0
25
50
75 100 125 150 175 200
T
S
– CASE TEMPERATURE – °C
Figure 2. Dependence of Safety Limiting Values on Temperature.