IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
[1]
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage
≤
300 V
rms
for rated mains voltage
≤
450 V
rms
for rated mains voltage
≤
600 V
rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
[2]
V
IORM
x 1.875=V
PR
, 100% Production Test with
t
m
=1 sec, Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5=V
PR
, Type and Sample Test,
t
m
=60 sec,Partial discharge < 5 pC
Highest Allowable Overvoltage(Transient Overvoltage
tin
i = 10 sec)
Safety-limiting values - maximum values allowed in the event of a failure.
Case Temperature
Input Current
[3]
Output Power
[3]
Insulation Resistance at T
S
, V
IO
= 500 V
V
IORM
V
PR
Symbol
HCPL-7860/786J Unit
I - IV
I - III
I - II
40/85/21
2
891
1670
V
peak
V
peak
V
PR
1336
V
peak
V
IOTM
T
S
I
S
,
INPUT
P
S, OUTPUT
R
S
OUTPUT POWER - P
S
, INPUT CURRENT - I
S
800
700
600
500
400
300
200
100
0
0
25
6000
175
400
600
>10
9
V
peak
°C
mA
mW
Ω
P
S
(mW)
I
S
(mA)
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be
ensured by protective circuits within the application. Surface Mount Classifications is Class A in
accordance with CECC00802.
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog,
under Product Safety Regulations section, (IEC/EN/DIN EN 60747-5-2) for a detailed description
of Method a and Method b partial discharge test profiles.
3. Refer to the following figure for dependence of P
S
and I
S
on ambient temperature.
50 75 100 125 150 175 200
T
S
- CASE TEMPERATURE -
o
C
Insulation and Safety Related Specifications
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
Parameter
Symbol
DIP-8
7.4
8.0
0.5
SO-16
8.3
8.3
0.5
Units
mm
mm
mm
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Minimum External Air Gap L(101)
(Clearance)
Minimum External
Tracking (Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
CTI
L(102)
>175
>175
V
IIIa
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
6