IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage
≤150
V rms
for rated mains voltage
≤300
V rms
for rated mains voltage
≤450
V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b†
V
IORM
x 1.875 = V
PR
, 100% Production
Test with t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a†
V
IORM
x 1.5 = V
PR
, Type and Sample Test,
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage†
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature
Input Current
Output Power
Insulation Resistance at T
S
, V
10
= 500 V
Symbol
HCPL-7710
Option 060
I-IV
I-IV
I-III
55/100/21
2
630
1181
HCPL-0710
Option 060
I-IV
I-III
55/100/21
2
560
1050
Units
V
IORM
V
PR
V peak
V peak
V
PR
945
840
V peak
V
IOTM
6000
4000
V peak
T
S
I
S,INPUT
P
S,OUTPUT
R
IO
175
230
600
≥10
9
150
150
600
≥10
9
°C
mA
mW
†Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section
IEC/EN/DIN EN 60747-5-2, for a detailed description.
Note:
These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
Note:
The surface mount classification is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter
Storage Temperature
Ambient Operating Temperature
Supply Voltages
Input Voltage
Output Voltage
Input Current
Average Output Current
Lead Solder Temperature
Solder Reflow Temperature Profile
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Supply Voltages
Logic High Input Voltage
Logic Low Input Voltage
Input Signal Rise and Fall Times
5
Symbol
T
S
T
A
V
DD1
, V
DD2
V
I
V
O
I
I
I
O
Max.
Units
125
°C
+100
°C
6.0
Volts
V
DD1
+0.5
Volts
V
DD2
+0.5
Volts
+10
mA
10
mA
260°C for 10 sec., 1.6 mm below seating plane
See Solder Reflow Temperature Profile Section
Min.
–55
–40
0
–0.5
–0.5
–10
Figure
Symbol
T
A
V
DD1
, V
DD2
V
IH
V
IL
t
r
, t
f
Min.
–40
4.5
2.0
0.0
Max.
+100
5.5
V
DD1
0.8
1.0
Units
°C
V
V
V
ms