Electrical Specifications (DC)
Over recommended operating conditions (T
A
= -40 to 100°C, I
F(ON)
= 7 to 16 mA, V
F(OFF)
= -3.0 to 0.8 V,
V
CC
= 15 to 30 V, V
EE
= Ground) unless otherwise specified.
Parameter
High Level
Output Current
Low Level
Output Current
Symbol
I
OH
I
OL
Min.
Typ.* Max. Units
0.5
1.5
A
2.0
A
0.5
2.0
A
2.0
A
(V
CC
- 4) (V
CC
- 3)
V
0.1
2.0
2.0
2.3
0.5
5.0
5.0
5.0
V
mA
mA
mA
Test Conditions
V
O
= (V
CC
- 4 V)
V
O
= (V
CC
- 15 V)
V
O
= (V
EE
+ 2.5 V)
V
O
= (V
EE
+ 15V)
I
O
= -100 mA
I
O
= 100 mA
Output Open,
I
F
= 7 to 16 mA
Output Open,
V
F
= -3.0 to +0.8 V
I
O
= 0 mA,
V
O
> 5 V
Fig.
2, 3,
17
5, 6,
18
1, 3,
19
4, 6,
20
7, 8
Note
5
2
5
2
6, 7
High Level Output
V
OH
Voltage
Low Level Output
V
OL
Voltage
High Level Supply
I
CCH
Current
Low Level Supply
I
CCL
Current
Threshold Input
I
FLH
Current Low to High
Threshold Input
Voltage High to Low
V
FHL
Input Forward
V
F
Voltage
Temperature
∆V
F
/∆T
A
Coefficient
of Forward Voltage
Input Reverse
BV
R
Breakdown Voltage
Input Capacitance
C
IN
UVLO Threshold
V
UVLO+
V
UVLO–
UVLO Hysteresis
UVLO
HYS
9, 15,
21
0.8
1.2
1.5
-1.6
1.8
V
V
I
F
= 10 mA
16
mV/°C I
F
= 10 mA
Ir = 10
µA
f = 1 MHz, V
F
= 0 V
V
O
> 5 V, I
F
= 10 mA
5
60
12.3
10.7
1.6
V
pF
V
11.0
9.5
13.5
12.0
22, 36
* All typical values at T
A
= 25°C and V
CC
- V
EE
= 30 V, unless otherwise noted.
1-186