Recommended Operating Conditions
Parameter
Power Supply Voltage
Symbol
V
CC
I
F(ON)
I
F(OFF)
T
A
HCPL-3100
HCPL-3101
Input Current (OFF)
HCPL-3100
HCPL-3101
Operating Temperature
Device
Min.
15
15
Input Current (ON)
12**
8**
-
-
-25
Max.
30*
24
24
16
0.6
0.2
80
Units
V
V
mA
mA
mA
mA
°C
*For T
A
= -10°C to 60°C.
**The initial switching threshold is 10 mA or less for the HCPL-3100 and 5 mA or less for the HCPL-3101.
Recommended Protection
for Output Transistors
During switching transitions, the
output transistors Q1 and Q2 of
the HCPL-3100/3101 can conduct
large amounts of current. Figure
1 describes a recommended
circuit design showing a current
limiting resistor R
2
which is
necessary in order to prevent
damage to the output transistors
Q1 and Q2. (See Note 7.) A
bypass capacitor C
1
is also recom-
mended to reduce power supply
noise.
+5 V
HCPL-3100/1
8
R
3
7
ANODE
Q2
6
TTL
OR
LSTTL
TOTEM
POLE
OUTPUT
GATE
R
2
CATHODE
Q1
5
12V
12V
+ HVDC
C
1
CONTROL
INPUT
IGBT
(OR
MOSFET)
3-PHASE
AC
- HVDC
R
2
= 25 - 100
Ω
R
3
= 180
Ω
(HCPL-3100)
240
Ω
(HCPL-3101)
BYPASS CAPACITOR C
1
= 0.1
µF
Figure 1. Recommended Output Transistor Protection and Typical Application Circuit.
1-341