欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-2630 参数 Datasheet PDF下载

HCPL-2630图片预览
型号: HCPL-2630
PDF下载: 下载PDF文件 查看货源
内容描述: 高CMR ,高速TTL兼容光电耦合器 [High CMR, High Speed TTL Compatible Optocouplers]
分类和应用: 光电输出元件
文件页数/大小: 20 页 / 256 K
品牌: AGILENT [ AGILENT TECHNOLOGIES, LTD. ]
 浏览型号HCPL-2630的Datasheet PDF文件第4页浏览型号HCPL-2630的Datasheet PDF文件第5页浏览型号HCPL-2630的Datasheet PDF文件第6页浏览型号HCPL-2630的Datasheet PDF文件第7页浏览型号HCPL-2630的Datasheet PDF文件第9页浏览型号HCPL-2630的Datasheet PDF文件第10页浏览型号HCPL-2630的Datasheet PDF文件第11页浏览型号HCPL-2630的Datasheet PDF文件第12页  
VDE 0884 Insulation Related Characteristics
(HCPL-2611 Option 060 Only)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage
300 V rms
for rated mains voltage
450 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and sample test,
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
Insulation Resistance at T
S
, V
IO
= 500 V
Symbol
Characteristic
I-IV
I-III
55/85/21
2
630
1181
Units
V
IORM
V
PR
V
peak
V
peak
V
PR
945
V
peak
V
IOTM
6000
V
peak
T
S
I
S,INPUT
P
S,OUTPUT
R
S
175
230
600
10
9
°C
mA
mW
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section (VDE 0884), for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application.
VDE 0884 Insulation Related Characteristics (HCNW137/2601/2611 Only)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage
600 V rms
for rated mains voltage
1000 V rms
Climatic Classification (DIN IEC 68 part 1)
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and sample test,
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
Insulation Resistance at T
S
, V
IO
= 500 V
Symbol
Characteristic
I-IV
I-III
55/100/21
2
1414
2651
Units
V
IORM
V
PR
V
peak
V
peak
V
PR
2121
V
peak
V
IOTM
8000
V
peak
T
S
I
S,INPUT
P
S,OUTPUT
R
S
150
400
700
10
9
°C
mA
mW
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section (VDE 0884), for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application.
1-153