10
Switching Specifications (AC)
Over Recommended Operating Conditions T = 0°C to 70°C, VCC = 3 V to 18 V, unless otherwise specified.
A
Device
Parameter
Symbol
HCPL-
Min. Typ.* Max. Units
Test Conditions
Fig. Note
Propagation
Delay Time
to Logic Low
at Output
tPHL
65
500
µs
IF = 40 µA, RL = 11 to 16 kΩ,
7, 9 9, 10
VCC = 3.3 to 5 V
3
25
30
T = 25°C
A
IF = 0.5 mA,
RL = 4.7 kΩ
Propagation
Delay Time
to Logic High
Output
tPLH
70
34
500
µs
IF = 40 µA, RL = 11 to 16 kΩ,
CC = 3.3 to 5 V
T = 25°C
7, 9 9, 10
V
60
90
IF = 0.5 mA,
A
RL = 4.7 kΩ
4701/4731
070A/073A
130
Common Mode |CMH|
Transient
Immunity at
Logic High
1,000 10,000
V/µs IF = 0 mA, RL = 4.7 to 11 kΩ,
CM = 10 Vp-p
T = 25°C,
8
8
6, 7
6, 7
V
,
A
Output
Common Mode |CML|
Transient
Immunity at
Logic Low
Output
1,000 10,000
2,000
V/µs IF = 0.5 mA, RL = 4.7 to 11 kΩ,
|VCM| = 10 Vp-p
,
T = 25°C
A
IF = 40 µA, RL = 11 to 16 kΩ,
|VCM| = 10 Vp-p
V
CC = 3.3 to 5 V, T = 25°C
A
*All typical values at T = 25°C and VCC = 5 V, unless otherwise noted.
A
Package Characteristics
Device
Parameter
Symbol HCPL- Min. Typ.* Max. Units Test Conditions Fig. Note
Input-Output Momentary
Withstand Voltage**
V
2500
V rms RH ≤ 50%,
t = 1 min.,
3, 4
3, 4a
3
ISO
TA = 25°C
Option 020
4701 5000
4731
Resistance
(Input-Output)
RI-O
CI-O
II-I
1012
0.6
Ω
VI-O = 500 VDC
RH ≤ 45%
Capacitance
(Input-Output)
pF
µA
f = 1 MHz
3
Insulation Leakage
Current (Input-Input)
4731
073A
0.005
1011
RH ≤ 45%, t = 5 s,
5
V = 500 VDC
I-I
Resistance (Input-Input)
RI-I
CI-I
Ω
Capacitance
(Input-Input)
4731
073A
0.03
0.25
pF
f = 1 MHz
5
*All typical values at TA = 25°C and VCC = 5 V.
**The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if appli-
cable),yourequipmentlevelsafetyspecificationorAgilentApplicationNote1074entitled“OptocouplerInput-OutputEndurance
Voltage.”