3
Recommended Operating Conditions
Parameter
Input Current, Low Level
Input Current, High Level
Supply Voltage, Output
Fan Out (R
L
= 1 kΩ)
Output Pull-Up Resistor
Operating Temperature
Symbol
I
FL
*
I
FH
V
CC
N
R
L
T
A
330
-40
Min.
0
5
4.5
Max.
250
15
5.5
5
4,000
85
Units
µA
mA
V
TTL
Loads
Ω
°C
* The off condition can also be guaranteed by ensuring that V
F
(off)
≤
0.8 volts.
Absolute Maximum Ratings
(No Derating Required up to 85°C)
Storage Temperature .................................................... -55°C to +125°C
Operating Temperature .................................................. -40°C to +85°C
Forward Input Current - I
F
(see Note 2) ....................................... 20 mA
Reverse Input Voltage - V
R
................................................................. 5 V
Supply Voltage - V
CC
(1 Minute Maximum) ........................................ 7 V
Output Collector Current - I
O
........................................................ 50 mA
Output Collector Power Dissipation ............................................ 85 mW
Output Collector Voltage - V
O
............................................................ 7 V
(Selection for higher output voltages up to 20 V is available)
Infrared and Vapor Phase Reflow Temperature ....................... see below
TEMPERATURE – °C
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
∆T
= 145°C, 1°C/SEC
∆T
= 115°C, 0.3°C/SEC
∆T
= 100°C, 1.5°C/SEC
1
2
3
4
5
6
7
8
9
10
11
12
TIME – MINUTES
Maximum Solder Reflow Thermal Profile.
(Note: Use of Non-Chlorine Activated Fluxes is Recommended.)