欢迎访问ic37.com |
会员登录 免费注册
发布采购

16900 参数 Datasheet PDF下载

16900图片预览
型号: 16900
PDF下载: 下载PDF文件 查看货源
内容描述: 逻辑分析仪 [Logic Analyzer]
分类和应用:
文件页数/大小: 35 页 / 1054 K
品牌: AGILENT [ AGILENT TECHNOLOGIES, LTD. ]
 浏览型号16900的Datasheet PDF文件第18页浏览型号16900的Datasheet PDF文件第19页浏览型号16900的Datasheet PDF文件第20页浏览型号16900的Datasheet PDF文件第21页浏览型号16900的Datasheet PDF文件第23页浏览型号16900的Datasheet PDF文件第24页浏览型号16900的Datasheet PDF文件第25页浏览型号16900的Datasheet PDF文件第26页  
Agilent 16760A Specifications and Characteristics  
Agilent Technologies 16760A Supplemental Specifications* and Characteristics (continued)  
Asynchronous Timing Analysis (continued) Conventional Timing Analysis  
Transitional Timing Analysis  
(250 ps ꢀ 0.01ꢁ of sample period)  
< 1.5 ns  
Sample period accuracy  
Channel-to-channel skew  
Time interval accuracy  
(250 ps ꢀ 0.01ꢁ of sample period)  
< 1.5 ns  
[sample period ꢀ  
[sample period ꢀ  
(channel-to-channel skew) ꢀ  
(0.01ꢁ of time interval)]  
(channel-to-channel skew) ꢀ  
(0.01ꢁ of time interval)]  
Minimum data pulse width  
1.5 ns for data capture  
3.8 ns for data capture  
5.1 ns for trigger sequencing  
5.1 ns for trigger sequencing  
Maximum trigger sequencer speed  
Trigger resources  
200 MHz  
200 MHz  
16 Patterns evaluated as =, , >, <, , 16 Patterns evaluated as =, , >, <, , ≤  
15 Ranges evaluated as in range,  
not in range  
15 Ranges evaluated as in range,  
not in range  
2 Edge/glitch  
2 Edge/glitch  
(2 Timers per module) – 1  
2 Global counters  
(2 Timers per module) – 1  
2 Global counters  
1 Occurrence counter per sequence level 1 Occurrence counter per sequence level  
4 Flags, Arm In  
4 Flags, Arm In  
Trigger resource conditions  
Trigger actions  
Arbitrary Boolean combinations  
Arbitrary Boolean combinations  
Goto  
Goto  
Trigger and fill memory  
Trigger and goto  
Trigger and fill memory  
Trigger and goto  
Timer start/stop/pause/resume  
Global counter increment/reset  
Occurrence counter reset  
Timer/start/stop/pause/resume  
Global counter increment/reset  
Occurrence counter reset  
Maximum global counter  
Maximum occurrence counter  
Timer value range  
16,777,215  
16,777,215  
16,777,215  
16,777,215  
100 ns to 4397 seconds  
100 ns to 4397 seconds  
Timer resolution  
4 ns  
4 ns  
Timer accuracy  
(10 ns ꢀ 0.01ꢁ)  
(10 ns ꢀ 0.01ꢁ)  
Greater than duration  
5 ns to 83 ms in 5 ns increments  
5 ns to 83 ms in 5 ns increments  
Less than duration  
10 ns to 83 ms in 5 ns increments  
10 ns to 83 ms in 5 ns increments  
Timer reset latency  
60 ns  
60 ns  
Data in to BNC port out delay latency  
Flag set/reset to evaluation latency  
150 ns  
110 ns  
150 ns  
110 ns  
Environmental  
Operating temperature  
0 deg C to 45 deg C  
22  
 复制成功!