T9000  
Preliminary Data Sheet  
November 2000  
ISDN Network Termination Node (NTN) Device  
17 Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent or latent damage to the device. These  
are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in  
excess of those given in the operation sections of the data sheet. Exposure to absolute maximum ratings for  
extended periods can adversely affect device reliability.  
External leads can be soldered safely at temperatures up to 300 °C.  
Table 117. Absolute Maximum Ratings  
Parameter  
dc Supply Voltage Range  
Symbol  
VDD  
Min  
–0.5  
–55  
Max  
6.5  
Unit  
V
Storage Temperature  
Tstg  
150  
6.5  
°C  
V
Voltage (any pin) with Respect to GND  
–0.5  
18 Handling Precautions  
Although protection circuitry has been designed into this device, proper precautions should be taken to avoid expo-  
sure to electrostatic discharge (ESD) during handling and mounting. Lucent employs a human-body model (HBM)  
and charged-device model (CDM) for ESD-susceptibility testing and protection design evaluation. ESD voltage  
thresholds are dependent on the circuit parameters used to define the model. No industry-wide standard has been  
adopted for the CDM. However, a standard HBM (resistance = 1500 Ω, capacitance = 100 pF) is widely used and,  
therefore, can be used for comparison. The HBM ESD threshold presented here was obtained by using the circuit  
parameters shown below.  
Table 118. ESD Threshold Voltage  
Device  
Voltage  
T9000  
>500  
19 Recommended Operating Conditions  
Table 119. Recommended Operating Conditions  
Parameter  
Ambient Temperature  
Any VDD  
Symbol  
TA  
Test Condition  
Min  
–40  
Typ  
Max  
85  
Unit  
°C  
VDD = 5 V ± 5%  
VDD  
4.75  
5.0  
5.25  
10  
V
GND to GND  
VGG  
–10  
mV  
µF  
Voltage Ref Capacitor  
Master Clock Frequency  
Master Clock Tolerance  
CVR  
MCLK  
MCLK  
0.08  
0.1  
0.2  
15.36  
MHz  
NT Mode  
LT Mode  
–225*  
–225 + x*†  
47  
–225*  
–225 + x*†  
53  
ppm  
ppm  
Master Clock Duty Cycle  
MCLK  
%
* To meet ANSI T1.601 free-run line rate requirement, NT tolerance is 100 ppm.  
† x = tolerance of MTC.  