L9215A/G  
Short-Loop Sine Wave Ringing SLIC  
Data Sheet  
September 2001  
Hybrid Balance  
ac Applications (continued)  
Design Examples (continued)  
Receive Gain  
Set the hybrid cancellation via RHB.  
RX  
gRCV × gTX  
------------------------------  
RHB =  
If a 5 V only codec such as the Agere T7504 is used,  
dc blocking capacitors must be added as shown in  
Figure 25. This is because the codec is referenced to  
2.5 V and the SLIC to ground—with the ac coupling, a  
dc bias at T/R is eliminated and power associated with  
this bias is not consumed.  
Ratios of RRCV, RT3, and RGP will set both the low-fre-  
quency termination and receive gain for the complex  
case. In the complex case, additional high-frequency  
compensation, via CN, RN1, and RN2, is needed for the  
return loss characteristic. For resistive termination, CN,  
RN1, and RN2 are not used and RCVN is tied to ground  
via a resistor.  
Typically, values of 0.1 µF to 0.47 µF capacitors are  
used for dc blocking. The addition of blocking capaci-  
tors will cause a shift in the return loss and hybrid bal-  
ance frequency response toward higher frequencies,  
degrading the lower-frequency response. The lower  
the value of the blocking capacitor, the more pro-  
nounced the effect is, but the cost of the capacitor is  
lower. It may be necessary to scale resistor values  
higher to compensate for the low-frequency response.  
This effect is best evaluated via simulation. A PSPICE®  
model for the L9215 is available.  
Determine the receive gain, gRCV, taking into account  
the impedance transformation in a manner similar to  
transmit gain.  
REQ  
RX (dB) = RX (specified[dB]) + 20log ----------  
600  
RX (dB) = 20log gRCV  
Then:  
4
-----------------------------------------------  
RRCV RRCV  
gRCV =  
--------------- ---------------  
1 +  
+
Design equation calculations seldom yield standard  
component values. Conversion from the calculated  
value to standard value may have an effect on the ac  
parameters. This effect should be evaluated and opti-  
mized via simulation.  
RT3  
RGP  
and low-frequency termination  
2400  
--------------------------------------------  
ZTER(low) =  
+ 2RP + 50 Ω  
RT3  
RT3  
----------- ---------------  
1 +  
+
RGP RRCV  
ZTER(low) is the specified termination impedance assum-  
ing low frequency (C or C´ is open).  
RP is the series protection resistor.  
50 is the typical internal feed resistance.  
These two equations are best solved using a computer  
spreadsheet.  
Next, solve for the high-frequency return loss compen-  
sation circuit, CN, RN1, and RN2:  
2RP  
CNRN2 = ------------ CG RTGP  
2400  
RTGS  
-------------  
2400  
2RP  
RN1 = RN2 ------------  
1  
RTGP  
There is an input offset voltage associated with nodes  
RCVN and RCVP. To minimize the effect of mismatch  
of this voltage at T/R, the equivalent resistance to ac  
ground at RCVN should be approximately equal to that  
at RCVP. Refer to Figure 25 (with dc blocking capaci-  
tors). To meet this requirement, RN2 = RGP || RT3.  
Agere Systems Inc.  