CW20P-Type
CW Tunable, Wavelength-Stabilized Laser Module
Advance Data Sheet, Rev. 1
June 2001
Characteristics
(continued)
Table 3. Optical Characteristics
Parameter
Average Optical-Fiber Power Output (BOL)
1
Output Power Variation (BOL)
Frequency Drift
Center Wavelength Range (See Table 6.)
Side-mode Suppression Ratio
2
Symbol
P
F
∆P
∆λ
C
λ
C
SMSR
Min
13.0
–0.5
–2.5
1528.77
32
Typ
—
—
—
—
—
Max
—
0.5
2.5
1610.53
—
Unit
dBm
dB
GHz
nm
dB
1. Output power definitions and measurement per ITU-T Recommendation G.957.
2. Ratio of the average output power in the dominant longitudinal mode to the power in the most significant side mode under fully
modulated conditions.
Qualification and Reliability
To help ensure high product reliability and customer satisfaction, Agere Systems is committed to an intensive qual-
ity program that starts in the design phase and proceeds through the manufacturing process. Optoelectronics mod-
ules are qualified to Agere Systems internal standards using MIL-STD-883 test methods and procedures and using
sampling techniques consistent with
Telcordia Technologies
requirements. This qualification program fully meets
the intent of
Telcordia
reliability practices TR-NWT-000468 and TA-TSY-000983. In addition, the Agere Systems
design, development, and manufacturing facility has been certified to be in full compliance with the latest
ISO
*
9001 Quality System Standards.
Laser Safety Information
Class IIIb Laser Product
All versions of the CW20P-type modules are classified as Class IIIb laser products per FDA/CDRH, 21 CFR 1040
Laser Safety requirements. The device will be classified with the FDA under an accession number to be deter-
mined.
This product complies with 21 CFR 1040.10 and 1040.11.
8
µm/125 µm
diameter single-mode fiber pigtail with 914
µm
tight-buffered jacket and connector.
Product is not shipped with power supply.
Caution: Use of controls, adjustments, and procedures other than those specified herein may result in
hazardous laser radiation exposure.
DANGER
INVISIBLE LASER RADIATION
IS EMITTED FROM THE END
OF FIBER OR CONNECTOR
Avoid direct exposure to beam
Do not view beam directly with
optical instruments
INVISIBLE LASER RADIATION EMITTED FROM END OF FIBER OR CONNECTOR
Avoid exposure to beam
Class IIIb Laser Product FDA/CDRH, 21 CFR 1040 Max. Output: 40 mW
Wavelength: 1.5
µm
*
ISO
is a registered trademark of The International Organization for Standardization.
4
Agere Systems Inc.