L7583A/B/C/D Line Card Access Switch
Data Sheet
February 2001
Handling Precautions
Although protection circuitry has been designed into this device, proper precautions should be taken to avoid expo-
sure to electrostatic discharge (ESD) during handling and mounting. Lucent Technologies Microelectronics Group
employs a human-body model (HBM) and a charged-device model (CDM) for ESD-susceptibility testing and pro-
tection design evaluation. ESD voltage thresholds are dependent on the circuit parameters used to define the
model. No industry-wide standard has been adopted for CDM. However, a standard HBM (resistance = 1500
Ω,
capacitance = 100 pF) is widely used and therefore can be used for comparison purposes. The HBM ESD thresh-
old presented here was obtained by using these circuit parameters.
Table 3. HBM ESD Threshold Voltage
Device
L7583
Rating
1000 V
Electrical Characteristics
T
A
= –40 °C to +85 °C, unless otherwise specified.
Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are
the result of engineering evaluations. Typical values are for information purposes only and are not part of the test-
ing requirements.
Table 4. Power Supply Specifications
Supply
V
DD
Min
4.5
Typ
5
Max
5.5
Unit
V
Supply
V
BAT
*
Min
–19
Typ
—
Max
–72
Unit
V
* V
BAT
is used only as a reference for internal protection circuitry. If V
BAT
rises above –10 V, the device will enter an all OFF state and remain in
this state until the battery voltage drops below –15 V.
Table 5. Test In Switches, 1 and 2
Parameter
OFF-state Leakage Current:
+25 °C
+85 °C
–40 °C
ON-resistance:
+25 °C
+85 °C
–40 °C
Isolation:
+25 °C
+85 °C
–40 °C
dV/dt Sensitivity*
Test Condition
Vswitch (differential) = –320 V to Gnd
Vswitch (differential) = –60 V to +260 V
Vswitch (differential) = –330 V to Gnd
Vswitch (differential) = –60 V to +270 V
Vswitch (differential) = –310 V to Gnd
Vswitch (differential) = –60 V to +250 V
Iswitch (on) = ±5 mA, ±10 mA
Iswitch (on) = ±5 mA, ±10 mA
Iswitch (on) = ±5 mA, ±10 mA
Vswitch (both poles) = ±320 V,
Logic inputs = Gnd
Vswitch (both poles) = ±330 V,
Logic inputs = Gnd
Vswitch (both poles) = ±310 V,
Logic inputs = Gnd
—
Measure
Iswitch
Iswitch
Iswitch
Min Typ Max
—
—
—
—
—
—
1
1
1
Unit
µA
µA
µA
∆
V
ON
∆
V
ON
∆
V
ON
Iswitch
Iswitch
Iswitch
—
—
—
—
—
—
—
—
45
—
33
—
—
—
200
—
70
—
1
1
1
—
Ω
Ω
Ω
µA
µA
µA
V/µs
* Applied voltage is 100 Vp-p square wave at 100 Hz.
4