Data Sheet  
November 1999  
L7582 Tip Ring Access Switch  
Electrical Characteristics (continued)  
Table 8. Loop Access Switches, 5 and 6  
Parameter  
Test Condition  
Measure Min Typ Max Unit  
OFF-state Leakage  
Current:  
Vswitch (differential) = –320 V to Gnd  
Vswitch (differential) = –60 V to +260 V  
Vswitch (differential) = –330 V to Gnd  
Vswitch (differential) = –60 V to +270 V  
Vswitch (differential) = –310 V to Gnd  
Vswitch (differential) = –60 V to +250 V  
Iswitch  
Iswitch  
Iswitch  
1
1
1
µA  
µA  
µA  
+25 °C  
+85 °C  
–40 °C  
dc Current Limit:  
+85 °C  
Vswitch (on) = ±10 V  
Vswitch (on) = ±10 V  
Iswitch  
Iswitch  
80  
mA  
–40 °C  
250 mA  
Dynamic Current Limit  
(t = <0.5 µs)  
Break switches in ON state; ringing access  
switches off; apply ±1000 V at 10/1000 µs pulse;  
appropriate secondary protection in place  
Iswitch  
2.5  
A
ON-resistance:  
+25 °C  
Iswitch (on) = ±10 mA, ±40 mA  
Iswitch (on) = ±10 mA, ±40 mA  
Iswitch (on) = ±10 mA, ±40 mA  
VON  
VON  
VON  
45  
33  
70  
+85 °C  
–40 °C  
ON-state Voltage*  
Iswitch = ILIMIT @ 50 Hz/60 Hz  
VON  
130  
V
Isolation:  
+25 °C  
+85 °C  
–40 °C  
Vswitch (both poles) = ±320 V, Logic inputs = Gnd  
Vswitch (both poles) = ±330 V, Logic inputs = Gnd  
Vswitch (both poles) = ±310 V, Logic inputs = Gnd  
Iswitch  
Iswitch  
Iswitch  
1
1
1
µA  
µA  
µA  
dV/dt Sensitivity†  
200  
V/µs  
* This parameter is not tested in production. Choice of secondary protector should ensure this rating is not exceeded.  
† Applied voltage is 100 Vp-p square wave at 100 Hz.  
6