Data Sheet  
March 1997  
L7554 Low-Power SLIC  
Accounting for VSAT tolerance of 0.5 V, a nominal  
overhead of 9.9 V would ensure transmission of an  
undistorted 2.2 V metering signal.  
Applications (continued)  
dc Applications (continued)  
Adjusting Overhead Voltage  
To adjust the open loop 2-wire voltage, pin DCR is  
programmed at the midpoint of a resistive divider from  
ground to either –5 V or VBAT. In the case of –5 V, the  
overhead voltage will be independent of the battery  
voltage. Figure 27 shows the equivalent input circuit to  
adjust the overhead.  
RP  
ROC/2  
ROC/2  
+
+
VT/R  
[ZT/R]  
VAMP  
RP  
R1  
25 kΩ ± 30%  
12-2563 (C)  
DCR  
R2  
Figure 26. SLIC 2-Wire Output Stage  
–5 V  
In addition to the required peak signal level, the SLIC  
needs about 2 V from each power supply to bias the  
amplifier circuitry. It can be thought of as an internal  
saturation voltage. Combining the saturation voltage  
and the peak signal level, the required overhead can be  
expressed as:  
12-2562 (C)  
Figure 27. Equivalent Circuit for Adjusting the  
Overhead Voltage  
Λ
2(RP +40 )  
VOH = VSAT + 1 +  
v
T R  
-----------------------------  
ZT R  
The overhead voltage is programmed by using the fol-  
lowing equation:  
2(RP +40 )  
2 ZT R  
VSAT + 1 +  
--------------- × 10dBm 20  
1000  
=
-----------------------------  
VOH = 6.5 – 4 VDCR  
ZT R  
where VSAT is the combined internal saturation voltage  
between the Tip/Ring amplifiers and VSAT (4.0 V typ.).  
RP () is the protection resistor value, and 40 is the  
output series resistance of each internal amplifier.  
ZT/R () is the ac loop impedance.  
||  
R1 25 kΩ  
= 6.5 4 5 ×  
-------------------------------------  
||  
R2 +R1 25 kΩ  
||  
R1 25 kΩ  
Example 1, On-hookTransmission of a Meter Pulse:  
= 6.5 + 20  
-------------------------------------  
+ R1 ||  
R2  
25 kΩ  
Signal level: 2.2 Vrms into 200 Ω  
35 protection resistors  
ILOOP = 0 (on-hook transmission of the metering  
signal)  
2(35 + 40)  
VOH = 4.0 + 1 + --------------------------- 2(2.2)  
200  
= 9.4 V  
Lucent Technologies Inc.  