NetLight
2417K4A 1300 nm Laser
2.5 Gbits/s Transceiver
Data Sheet, Rev. 1
August 2001
Application Information
(continued)
Transceiver Processing
When the process plug is placed in the transceiver's optical port, the transceiver and plug can withstand normal
wave soldering and aqueous spray cleaning processes. However, the transceiver is not hermetic, and should not
be subjected to immersion in cleaning solvents. The transceiver case should not be exposed to temperatures in
excess of 125
°C.
The transceiver pins can be wave soldered at 250
°C
for up to 10 seconds. The process plug
should only be used once. After removing the process plug from the transceiver, it must not be used again as a pro-
cess plug; however, if it has not been contaminated, it can be reused as a dust cover.
Transceiver Optical and Electrical Characteristics
Table 2. Transmitter Optical and Electrical Characteristics
(T
C
= 0
°C
to 70
°C;
V
CC
= 3.135 V—3.465 V)
Parameter
Average Optical Output Power (EOL)
Optical Wavelength
Spectral Width
Dynamic Extinction Ratio
Output Optical Eye
Power Supply Current
Input Data Voltage:
Single Ended*
Differential*
Transmit Disable Voltage
†
Transmit Enable Voltage
†
Symbol
Min
Max
Unit
P
O
–10.0
–3.0
dBm
λ
C
1266
1360
nm
∆λ
RMS
—
4
nm
EXT
8.2
—
dB
Compliant with SONET GR-253-CORE and
ITU-T G.957 Eye Mask Requirements
I
CCT
—
190
mA
V
INp-p
V
INp-p
V
D
V
EN
150
300
V
CC
– 0.9
V
EE
800
1600
V
CC
V
EE
+ 0.8
mVp-p
mVp-p
V
V
* 50 ¾ load, measured single ended. Differential operation is necessary for optimum performance. (See Figure 2 for visual representation.)
† TTL compatible interface.
Table 3. Receiver Optical and Electrical Characteristics
(T
C
= 0
°C
to 70
°C;
V
CC
= 3.135 V—3.465 V)
Parameter
Average Sensitivity:*
800 mV (CML) Differential Input To Transmitter
Maximum Input Power*
Power Supply Current
Output Data Voltage:
Single Ended
†
Differential
†
Signal-detect Switching Threshold:
Assert
Deassert
Signal-detect Hysteresis
Signal-detect Voltage:
‡
Low
High
Signal-detect Response Time
Symbol
P
I
P
MAX
I
CCR
V
OUTp-p
V
OUTp-p
LST
D
LST
I
HYS
V
OL
V
OH
SDRT
Min
—
–3
—
300
600
–45
—
0.5
0.0
2.4
—
Max
–18
—
110
500
1000
–19
–18.5
6
0.8
V
CC
100
Unit
dBm
dBm
mA
mVp-p
mVp-p
dBm
dBm
dB
V
V
µs
* 2
23
– 1 PRBS with a BER of 1 x 10
–10
.
† 50 ¾ load, measured single ended. Differential operation is necessary for optimum performance.(See Figure 2 for visual representation.)
‡ TTL compatible interface.
4
Agere Systems Inc.