1738U-Type Small Form-Factor
Erbium-Doped Fiber Amplifier with Uncooled Pump
Preliminary Data Sheet
March 2001
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Parameter
Symbol
Min
Max
Unit
Operating Case Temperature Range
Storage Case Temperature Range
Laser Forward Current
TOP
Tstg
IF
–5
–40
—
70
85
°C
°C
mA
V
500
2.5
Laser Reverse Voltage
VR
—
Electrical/Optical Operational Characteristics
Table 1. Optical/Electrical Characteristics
Parameter
Wavelength Range
Symbol
Conditions
Min
Max
Unit
λ
—
1528
–5
1562
—
nm
Optical Output Power
Optical Input Power
Noise Figure
POUT
PIN
PIN = –30 dBm to –8 dBm
—
dBm
dBm
–30
–8
NF
PIN = –30 dBm
PIN = –20 dBm
PIN = –15 dBm
PIN = –8 dBm
—
—
—
—
5.5
5.7
6.8
8.5
dB
dB
dB
dB
Operating Laser Forward Current
Operating Laser Forward Voltage
Power Consumption
IF,OP
VF,OP
PC
—
—
—
—
—
—
—
350
2.5
mA
V
875
–20
mW
dBm
ASE Noise Power at Optical Input Port
PASE,I
PIN = –30 dBm,
POUT = –5 dBm
Output Leakage Pump Power
PLEAK,O
PIN = –30 dBm,
POUT = –5 dBm,
λ = 1562 nm
—
–26
dBm
Reverse Isolation
IISO
RTAP
PDG
PMD
RLI
PIN = –30 dBm
25
0.032
—
—
0.063
0.5
0.5
—
dB
A/W
dBp-p
ps
Input Monitor Tap Responsivity
Polarization Sensitivity
—
—
—
—
—
Polarization Mode Dispersion
Optical Input Return Loss
Optical Output Return Loss
—
30
dB
RLO
30
—
dB
2
Agere Systems Inc.