Data Sheet, Rev 1.
August 2001
NetLight
1430G5 Type SONET/SDH
Long-Reach Transceivers with Clock Recovery
Application Information
(continued)
Table 3. Receiver Optical and Electrical Characteristics
(T
C
= –40
°C
to +85
°C;
V
CC
= 3.135 V—3.465 V)
Parameter
Average Sensitivity:
*
L-1.1
Maximum Input Power L-1.1
*
Link Status Switching Threshold:
Decreasing Light L-1.1
Increasing Light L-1.1
Link Status Hysteresis
Power Supply Current
Output Data Voltage/Clock Voltage:
Low
High
Signal Detect Output Voltage:
Low
High
Clock Duty Cycle
Output Clock Random Jitter
Output Clock Random Jitter Peaking
Clock/Data Alignment L-1.1 (See Figure 2.)
Jitter Tolerance/Jitter Transfer
* For 1 x 10
–10
BER with an optical input using 2
23
– 1 PRBS.
Symbol
P
I
P
MAX
LST
D
LST
I
HYS
I
CCR
V
OL
V
OH
V
OL
V
OH
DC
J
C
J
P
TCDA
Min
—
–10
–45
—
0.5
—
V
CC
– 1.86
V
CC
– 1.025
0.0
2.4
45
—
—
–0.8
Max
–34
—
–35
–34.5
6.0
200
V
CC
– 1.50
V
CC
– 0.88
0.8
V
CC
55
0.01
0.1
0.8
Unit
dBm
dBm
dBm
dBm
dB
mA
V
V
V
V
%
UI
dB
ns
Telcordia Technologies™
GR-253-CORE and
ITU-TG.958 Compliant
DATA
OUT
50%
CLOCK
OUT
50%
T
CDA
1-725(F).b
Figure 2. Clock/Data Alignment
Agere Systems Inc.