欢迎访问ic37.com |
会员登录 免费注册
发布采购

ACT5260PC-P10-POD 参数 Datasheet PDF下载

ACT5260PC-P10-POD图片预览
型号: ACT5260PC-P10-POD
PDF下载: 下载PDF文件 查看货源
内容描述: ACT5260PC - P10 -POD FR4适配器 [ACT5260PC-P10-POD FR4 Adapter]
分类和应用: 外围集成电路PC时钟
文件页数/大小: 10 页 / 202 K
品牌: AEROFLEX [ AEROFLEX CIRCUIT TECHNOLOGY ]
 浏览型号ACT5260PC-P10-POD的Datasheet PDF文件第1页浏览型号ACT5260PC-P10-POD的Datasheet PDF文件第2页浏览型号ACT5260PC-P10-POD的Datasheet PDF文件第4页浏览型号ACT5260PC-P10-POD的Datasheet PDF文件第5页浏览型号ACT5260PC-P10-POD的Datasheet PDF文件第6页浏览型号ACT5260PC-P10-POD的Datasheet PDF文件第7页浏览型号ACT5260PC-P10-POD的Datasheet PDF文件第8页浏览型号ACT5260PC-P10-POD的Datasheet PDF文件第9页  
Application Considerations:
Although the device has a 4XXX PC 179 pin
PGA compatible footprint, it is not a drop-in
replacement since the RM5260 has a different
clocking scheme. The RM5260 does not
generate the system clocks the same as the
R4400, R4600 and R4700. Instead, the system
clock is an input, which is multiplied up to the
pipeline rate. On the adapter, the Tclock and
Rclock pins are floating; not connected to
anything. SYNCout and IOout are connected to
ground to commit possible unconnected CMOS
inputs to a level. Depending on the system
configuration, accommodating the clocking
difference can be as simple as a few re-routing
jumpers or generating divisors of the original
MasterClock and the addition of some
phase-skewing buffers to emulate the Rclock
and Tclock system clocks. In addition, the boot
time mode bit serial stream needs to be
scrutinized before plugging in a RM5260 into an
R4700 or R4400 socket. The R4700 is closest
to the RM5260 whereas the R4400 is quite
different.
Figure 2 is an example of what had to be done
to an Algorithmics P4000i (IDT79S460) Single
Board Computer which was originally configured
for an R4700 with a 50 MHz input clock (100
MHz pipeline) and a divide by 2 output clock (50
MHz bus rate). With three wire jumpers, the
ACT5260PC-P10-POD was up and running with
no changes to the boot and monitor PROM or
any recompilation of application programs. In
this case, the R4700's modebit stream
happened to be compatible, where a board
jumper used to change the output clocks (Tclock
and Rclock) from divide by 2 to divide by 3 had
the effect of changing the Pclock multiplier from
2 to 3, upping the pipeline rate up to 150 Mhz
without changing the board oscillator.
R4700
MASTER CLOCK
ACT5260PC
SysClk
RCLK
TCLK
RCLK
Oscillator
50MHz
Oscillator
50MHz
From
Figure 2 – Setup Example
To
Aeroflex Circuit Technology
3
SCD5260PC REV A 9/15/97 Plainview NY (516) 694-6700
TCLK