欢迎访问ic37.com |
会员登录 免费注册
发布采购

ACT4423-DFI 参数 Datasheet PDF下载

ACT4423-DFI图片预览
型号: ACT4423-DFI
PDF下载: 下载PDF文件 查看货源
内容描述: ACT4423双收发器符合MIL -STD-一千七百六十〇分之一千五百五十三 [ACT4423 DUAL TRANSCEIVER FOR MIL-STD-1553/1760]
分类和应用: 电信集成电路
文件页数/大小: 7 页 / 97 K
品牌: AEROFLEX [ AEROFLEX CIRCUIT TECHNOLOGY ]
 浏览型号ACT4423-DFI的Datasheet PDF文件第2页浏览型号ACT4423-DFI的Datasheet PDF文件第3页浏览型号ACT4423-DFI的Datasheet PDF文件第4页浏览型号ACT4423-DFI的Datasheet PDF文件第5页浏览型号ACT4423-DFI的Datasheet PDF文件第6页浏览型号ACT4423-DFI的Datasheet PDF文件第7页  
ACT4423 DUAL TRANSCEIVER
FOR MIL-STD-1553/1760
Features
• +5 / +12 Volt Power Supply Operation
• Eliminates Negative Power Supply
• Low Power Dissipation
• Small Size & Light Weight
• Dual Transceivers Saves Space & Cost
• Outstanding MIL-STD-1553 performance
• Radiation Hard Dielectric Isolation Monolithic
Construction for Severe Environments
• Superior High Frequency Line Transient and
Input Ripple Rejection
• Input and Output TTL Compatible Design
• Processed and Screened to MIL-STD-883 Specs
• MIL-PRF-38534 Compliant Devices Available
• DESC SMD (Standard Military Drawing) Pending
CIRCUIT TECHNOLOGY
www.aeroflex.com
General Description
The Aeroflex Circuit Technology
ACT4423 is a next generation
monolithic transceiver design
which provides full compliance to
MIL-STD-1553A/B
and
1760
requirements in a small package
with low power consumption.
The ACT4423 series performs the
front-end
analog
function
of
inputting and outputting data
through a transformer to the
MIL-STD-1553 data bus.
Design of this transceiver reflects
particular attention to active filter
performance. This results in low bit
and word error rate with superior
waveform purity and minimal zero
crossover
distortion.
Efficient
transmitter electrical and thermal
design provides low internal power
dissipation and heat rise at high as
well as low duty cycles.
Each channel of the dual
transceiver is completely separate
from
the
other
and
fully
independent. This includes power
leads as well as signal lines. Hence,
each channel may be connected to
a different data bus with no
interaction.
TX DATA OUT
TX DATA IN
DRIVER
TX DATA IN
ACTIVE
FILTER
OUTPUT
STAGE
TX DATA OUT
TX INHIBIT IN
+5V (V
L
)
+12V (V
CC
)
GND1
GND2
GND3
RX DATA IN
RX DATA IN
CASE
RX STROBE IN
INPUT
AMPLIFIER
ACTIVE
FILTER
RX DATA OUT
COMP.
REFERENCE
RX DATA OUT
COMP.
Transmitter:
The Transmitter section accepts
bi-phase TTL data at the input and
when coupled to the data bus with a
1:1 ratio transformer, isolated on
the data bus side with two 52.5
Ohm fault isolation resistors, and
loaded
by
two
70
Ohm
terminations, the data bus signal is
Block Diagram (Without Transformer)
eroflex Circuit T
echnology
– Data Bus Modules For The Future © SCD4423 REV B 6/3/99