AMC8878/8879
ELECTRICAL CHARACTERISTICS
Unless otherwise specified, these specifications apply over the operating ambient temperature of 0°C to +70°C with
VIN = VOUT(NOMIAL) + 0.5V, and are for DC characteristics only. (Low duty cycle pulse testing techniques are used
which maintains junction and case temperatures equal to the ambient temperature.)
AMC8878/8879
Parameter
Symbol
Test Conditions
Units
%
Min Typ. Max
IOUT = 10mA, TA = +25OC
IOUT = 10 to 150mA
-1.4
-3
+1.4
+2
Output Voltage Accuracy
∆VOUT
Maximum Output Current
Current Limit
IOUT
150
160
mA
mA
ILIMIT
IOUT = 10mA
IOUT = 150mA
IOUT = 1mA
1.6
1.7
1.1
50
10
Ground Pin Current
IQ
µA
Dropout Voltage
VDROP
mV
IOUT = 50mA
120
I
OUT = 150mA
165
0
Line Regulation
Load Regulation
Ripple Rejection
-0.15
0.15 %/V
∆VOI VIN = (VOUT + 0.1V) to 6.5V, IOUT = 1mA
∆VOL IOUT = 10 to 120mA, COUT = 1µF
PSRR f=100Hz, IL=100uA
0.01 0.04 %/mA
50
30
20
dB
COUT = 10µF
OUT = 100µF
f = 10Hz - 100KHz,
BP = 0.01µF
Output Voltage Noise
en
µVRMS
C
C
Shutdown Input Threshold High
Shutdown Input Threshold Low
VSIH VIN = 2.5V to 5.5V
VSIL VIN = 2.5V to 5.5V
2.0
V
V
0.4
1
TA = +25OC
TA = +85OC
TA = +25OC
TA = +85OC
0.01
0.2
Shutdown Supply Current
IQ(SHDN) VOUT = 0V
µA
0.01 100
0.5
Shutdown Input Bias Current
ISHDN
V
SHDN = VIN
nA
TA = +25OC
TA = +85OC
6
6
C
BP = 0.1µF,
Shutdown Exit Delay
tdelay
ms
OC
COUT = 1µF, No load
Thermal Shutdown Temperature
TSHDN
+150
Note:
1. Current limit is measured at constant junction temperature, using pulse ON time.
2. Dropout is measured at constant junction temperature, using pulse ON time, and criterion is VOUT inside target value ± 2 %.
3. Regulation is measured at constant junction temperature, using pulsed ON time.
Copyright © 2006 ADDtek Corp.
4
DD067_G -- JUNE 2006