AMC2576  
APPLICATION INFORMATION (contd.)  
Feedback Connection  
For fixed output voltage version, the FB (feedback) pin must be connected to VOUT. For the adjustable version, it is  
important to place the output voltage ratio resistors near AMC2576 as possible in order to minimize the noise  
introduction.  
ENABLE  
It is required that the ENABLE must not be left open. For normal operation, connect this pin to a “LOW” voltage  
(typically, below 1.6V). On the other hand, for standby mode, connect this pin with a “HIGH” voltage. This pin can  
be safely pulled up to +VIN without a resistor in series with it.  
Grounding  
To maintain output voltage stability, the power ground connections must be low-impedance. For the 5-lead TO-220  
and TO-263 style package, both the tab and pin 3 are ground and either connection may be used.  
Heat Sink and Thermal Consideration  
Although the AMC2576 requires only a small heat sink for most cases, the following thermal consideration is  
important for all operation. With the package thermal resistances θJA and θJC, total power dissipation can be estimated  
as follows:  
PD = (VIN × IQ)+(VOUT / VIN)(ILOAD × VSAT);  
When no heat sink is used, the junction temperature rise can be determined by the following:  
TJ = PD × θJA;  
With the ambient temperature, the actual junction temperature will be:  
TJ = TJ +TA ;  
If the actual operating junction temperature is out of the safe operating junction temperature (typically 125°C), then a  
heat sink is required. When using a heat sink, the junction temperature rise will be reduced by the following:  
TJ = PD × (θJC + θinterface + θHeat sink);  
As one can see from the above, it is important to choose an heat sink with adequate size and thermal resistance, such  
that to maintain the regulator’s junction temperature below the maximum operating temperature.  
Copyright © 2006 ADDtek Corp.  
10  
DD007_E -- DECEMBER 2006  