欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADuM5401ARWZ 参数 Datasheet PDF下载

ADuM5401ARWZ图片预览
型号: ADuM5401ARWZ
PDF下载: 下载PDF文件 查看货源
内容描述: 四通道, 2.5千伏隔离带集成DC - DC转换器 [Quad-Channel, 2.5 kV Isolators with Integrated DC-to-DC Converter]
分类和应用: 转换器光电二极管
文件页数/大小: 28 页 / 539 K
品牌: ADI [ ADI ]
 浏览型号ADuM5401ARWZ的Datasheet PDF文件第20页浏览型号ADuM5401ARWZ的Datasheet PDF文件第21页浏览型号ADuM5401ARWZ的Datasheet PDF文件第22页浏览型号ADuM5401ARWZ的Datasheet PDF文件第23页浏览型号ADuM5401ARWZ的Datasheet PDF文件第24页浏览型号ADuM5401ARWZ的Datasheet PDF文件第26页浏览型号ADuM5401ARWZ的Datasheet PDF文件第27页浏览型号ADuM5401ARWZ的Datasheet PDF文件第28页  
Data Sheet  
ADuM5401/ADuM5402/ADuM5403/ADuM5404  
Table 27 illustrates how isoPower devices can provide many combinations of data channel count and multiples of the single unit power.  
Table 27. Configurations for Power and Data Channels  
Number of Data Channels  
Power Unit  
0 Channels  
2 Channels  
4 Channels  
6 Channels  
1-Unit Power  
ADuM5000 master  
ADuM520x master  
ADuM5401 to ADuM5404 master  
ADuM5401 to ADuM5404 master  
ADuM121x  
2-Unit Power  
3-Unit Power  
ADuM5000 master  
ADuM5000 slave  
ADuM5000 master  
ADuM5000 slave  
ADuM5000 slave  
ADuM5000 master  
ADuM520x slave  
ADuM5000 master  
ADuM5000 slave  
ADuM520x slave  
ADuM5401 to ADuM5404 master  
ADuM520x slave  
ADuM5401 to ADuM5404 master  
ADuM520x slave  
ADuM5401 to ADuM5404 master  
ADuM5000 slave  
ADuM5000 slave  
ADuM5401 to ADuM5404 master  
ADuM520x slave  
ADuM5000 slave  
In the case of unipolar ac or dc voltage, the stress on the insulation  
is significantly lower. This allows operation at higher working  
voltages while still achieving a 50-year service life. The working  
voltages listed in Table 20 can be applied while maintaining the  
50-year minimum lifetime, provided that the voltage conforms  
to either the unipolar ac or dc voltage cases.  
INSULATION LIFETIME  
All insulation structures eventually break down when subjected to  
voltage stress over a sufficiently long period. The rate of insulation  
degradation is dependent on the characteristics of the voltage  
waveform applied across the insulation. In addition to the testing  
performed by the regulatory agencies, Analog Devices carries  
out an extensive set of evaluations to determine the lifetime  
of the insulation structure within the ADuM5401/ADuM5402/  
ADuM5403/ADuM5404 devices.  
Any cross-insulation voltage waveform that does not conform  
to Figure 31 or Figure 32 should be treated as a bipolar ac wave-  
form and its peak voltage limited to the 50-year lifetime voltage  
value listed in Table 20. The voltage presented in Figure 32 is  
shown as sinusoidal for illustration purposes only. It is meant to  
represent any voltage waveform varying between 0 V and some  
limiting value. The limiting value can be positive or negative,  
but the voltage cannot cross 0 V.  
Analog Devices performs accelerated life testing using voltage levels  
higher than the rated continuous working voltage. Acceleration  
factors for several operating conditions are determined. These  
factors allow calculation of the time to failure at the actual working  
voltage. The values shown in Table 20 summarize the peak voltage  
for 50 years of service life for a bipolar ac operating condition  
and the maximum CSA/VDE approved working voltages. In  
many cases, the approved working voltage is higher than the  
50-year service life voltage. Operation at these high working  
voltages can lead to shortened insulation life in some cases.  
RATED PEAK VOLTAGE  
0V  
Figure 30. Bipolar AC Waveform  
The insulation lifetime of the ADuM5401/ADuM5402/  
ADuM5403/ADuM5404 devices depends on the voltage wave-  
form type imposed across the isolation barrier. The iCoupler  
insulation structure degrades at different rates depending on  
whether the waveform is bipolar ac, unipolar ac, or dc. Figure 30,  
Figure 31, and Figure 32 illustrate these different isolation  
voltage waveforms.  
RATED PEAK VOLTAGE  
0V  
Figure 31. DC Waveform  
RATED PEAK VOLTAGE  
Bipolar ac voltage is the most stringent environment. The goal  
of a 50-year operating lifetime under the bipolar ac condition  
determines the maximum working voltage recommended by  
Analog Devices.  
0V  
NOTES:  
1. THE VOLTAGE IS SHOWN AS SINUSOIDAL FOR ILLUSTRATION  
PURPOSES ONLY. IT IS MEANT TO REPRESENT ANY VOLTAGE  
WAVEFORM VARYING BETWEEN 0V AND SOME LIMITING VALUE.  
THE LIMITING VALUE CAN BE POSITIVE OR NEGATIVE, BUT THE  
VOLTAGE CANNOT CROSS 0V.  
Figure 32. Unipolar AC Waveform  
Rev. C | Page 25 of 28