ADuM1410/ADuM1411/ADuM1412
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Symbol Min Typ Max Unit
Test Conditions
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance2
RI-O
CI-O
CI
1012
Ω
pF
pF
2.2
4.0
f = 1 MHz
IC Junction-to-Case Thermal Resistance
Side 1
Side 2
θJCI
θJCO
33
28
°C/W
°C/W
Thermocouple located at center of package underside
1 The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2 Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM141x have been approved by the organizations listed in Table 5. See Table 10 and the Insulation Lifetime section for
recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL
CSA
VDE
TÜV
Recognized Under 1577
Component Recognition
Program1
Approved under CSA
Component Acceptance
Notice #5A
Certified according to DIN V VDE V
Approved according to:
0884-10 (VDE V 0884-10): 2006-122 IEC 60950-1:2005 and
EN 60950-1:2006
Double/reinforced insulation,
2500 V rms isolation voltage
Basic insulation per CSA
60950-1-03 and IEC 60950-1,
800 V rms (1131 V peak)
maximum working voltage.
Reinforced insulation, 560 V peak
3000 V rms reinforced isolation
at a 400 V rms working voltage.
3000 V rms basic isolation at a
600 V rms working voltage.
Reinforced insulation per
CSA 60950-1-03 and IEC
60950-1, 400 V rms (566 V
peak) maximum working
voltage.
File E214100
File 205078
File 2471900-4880-0001
Certificate B 10 03 56232 006
1 In accordance with UL 1577, each ADuM141x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 μA).
2 In accordance with DIN V VDE V 0884-10, each ADuM141x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge detection
limit = 5 pC). The asterisk (*) marked on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Symbol Value
Unit
Conditions
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
2500
7.7
V rms
1-minute duration
L(I01)
L(I02)
mm min Measured from input terminals to output terminals,
shortest distance through air
mm min Measured from input terminals to output terminals,
shortest distance path along body
Minimum External Tracking (Creepage)
8.1
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
0.017
>175
IIIa
mm min
V
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
CTI
Rev. H | Page 10 of 24