 浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第24页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第25页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第26页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第27页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第28页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第30页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第31页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第32页  
Data Sheet  
ADuM1400/ADuM1401/ADuM1402  
In the case of unipolar ac or dc voltage, the stress on the  
insulation is significantly lower, which allows operation at  
higher working voltages while still achieving a 50-year service  
life. The working voltages listed in Table 14 can be applied while  
maintaining the 50-year minimum lifetime, provided the voltage  
conforms to either the unipolar ac or dc voltage cases. Any cross-  
insulation voltage waveform that does not conform to Figure 22  
or Figure 23 should be treated as a bipolar ac waveform, and its  
peak voltage should be limited to the 50-year lifetime voltage  
value listed in Table 14.  
INSULATION LIFETIME  
All insulation structures eventually break down when subjected  
to voltage stress over a sufficiently long period. The rate of  
insulation degradation is dependent on the characteristics of  
the voltage waveform applied across the insulation. In addition  
to the testing performed by the regulatory agencies, Analog  
Devices carries out an extensive set of evaluations to determine  
the lifetime of the insulation structure within the ADuM140x.  
Analog Devices performs accelerated life testing using voltage  
levels higher than the rated continuous working voltage. Accel-  
eration factors for several operating conditions are determined.  
These factors allow calculation of the time to failure at the actual  
working voltage. The values shown in Table 14 summarize the  
peak voltage for 50 years of service life for a bipolar ac operating  
condition and the maximum CSA/VDE approved working  
voltages. In many cases, the approved working voltage is higher  
than a 50-year service life voltage. Operation at these high working  
voltages can lead to shortened insulation life in some cases.  
Note that the voltage presented in Figure 22 is shown as sinusoidal  
for illustration purposes only. It is meant to represent any voltage  
waveform varying between 0 V and some limiting value. The  
limiting value can be positive or negative, but the voltage cannot  
cross 0 V.  
RATED PEAK VOLTAGE  
0V  
Figure 21. Bipolar AC Waveform  
The insulation lifetime of the ADuM140x depends on the  
voltage waveform type imposed across the isolation barrier.  
The iCoupler insulation structure degrades at different rates  
depending on whether the waveform is bipolar ac, unipolar  
ac, or dc. Figure 21, Figure 22, and Figure 23 illustrate these  
different isolation voltage waveforms, respectively.  
RATED PEAK VOLTAGE  
0V  
Figure 22. Unipolar AC Waveform  
Bipolar ac voltage is the most stringent environment. The goal  
of a 50-year operating lifetime under the ac bipolar condition  
determines the Analog Devices recommended maximum  
working voltage.  
RATED PEAK VOLTAGE  
0V  
Figure 23. DC Waveform  