ADuM1200/ADuM1201  
PACKAGE CHARACTERISTICS  
Table 4.  
Parameter  
Symbol  
RI-O  
CI-O  
Min  
Typ  
1012  
1.0  
Max  
Unit  
pF  
Test Conditions  
Resistance (Input-Output)1  
Capacitance (Input-Output)1  
Input Capacitance  
f = 1 MHz  
CI  
4.0  
pF  
IC Junction-to-Case Thermal Resistance, Side 1  
θJCI  
46  
°C/W  
Thermocouple located at center of  
package underside  
IC Junction-to-Case Thermal Resistance, Side 2  
θJCO  
41  
°C/W  
1 The device is considered a 2-terminal device; Pins 1, 2, 3, and 4 are shorted together, and Pins 5, 6, 7, and 8 are shorted together.  
REGULATORY INFORMATION  
The ADuM1200/ADuM1201 have been approved by the following organizations:  
Table 5.  
UL  
CSA  
VDE  
Recognized under 1577 Component  
Recognition Program1  
Approved under CSA Component  
Acceptance Notice #5A  
Certified according to  
DIN EN 60747-5-2 (VDE 0884 Part 2): 2003-012  
2500 V rms isolation voltage  
Basic insulation, 560 V peak  
Complies with DIN EN 60747-5-2 (VDE 0884  
Part 2): 2003-01, DIN EN 60950 (VDE 0805): 2001-12;  
EN 60950: 2000, Reinforced insulation, 560 V peak  
File 2471900-4880-0001  
File E214100  
File 205078  
1 In accordance with UL1577, each ADuM120x is proof-tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 µA).  
2 In accordance with DIN EN 60747-5-2, each ADuM120x is proof-tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection  
limit = 5 pC).  
INSULATION AND SAFETY-RELATED SPECIFICATIONS  
Table 6.  
Parameter  
Symbol Value  
Unit  
V rms  
mm  
Conditions  
Rated Dielectric Insulation Voltage  
Minimum External Air Gap (Clearance)  
2500  
1 minute duration  
Measured from input terminals to output terminals, shortest  
distance through air  
L(I01)  
4.90 min  
Minimum External Tracking (Creepage) L(I02)  
4.01 min  
0.017 min  
>175  
mm  
mm  
V
Measured from input terminals to output terminals, shortest  
distance path along body  
Insulation distance through insulation  
Minimum Internal Gap (Internal  
Clearance)  
Tracking Resistance (Comparative  
Tracking Index)  
CTI  
DIN IEC 112/VDE 0303 Part 1  
Isolation Group  
IIIa  
Material Group (DIN VDE 0110, 1/89, Table 1)  