ADM206E/ADM207E/ADM208E/ADM211E/ADM213E  
Conducted emissions are measured by monitoring the line  
RADIATED EMISSIONS  
power supply. The equipment used consists of a LISN (Line  
Impedance Stabilizing Network) which essentially presents a  
fixed impedance at RF, and a spectrum analyzer. The spectrum  
analyzer scans for emissions up to 30 MHz and a plot for the  
ADM211E is shown in Figure 32.  
Radiated emissions are measured at frequencies in excess of  
30 MHz. RS-232 outputs designed for operation at high baud  
rates while driving cables can radiate high frequency EM energy.  
The reasons already discussed which cause conducted emissions  
can also be responsible for radiated emissions. Fast RS-232  
output transitions can radiate interference, especially when  
lightly loaded and driving unshielded cables. Charge pump  
devices are also prone to radiating noise due to the high fre-  
quency oscillator and high voltages being switched by the charge  
pump. The move towards smaller capacitors in order to con-  
serve board space has resulted in higher frequency oscillators  
being employed in the charge pump design. This has resulted in  
higher levels of emission, both conducted and radiated.  
S3  
S1  
V
V+ = 2V  
CC  
CC  
C1  
C3  
S2  
S4  
V
GND  
CC  
INTERNAL  
OSCILLATOR  
The RS-232 outputs on the ADM2xxE products feature a con-  
trolled slew rate in order to minimize the level of radiated emis-  
sions, yet are fast enough to support data rates up to 230 kBaud.  
Figure 30. Charge Pump Voltage Doubler  
RADIATED NOISE  
ø1  
DUT  
TO  
RECEIVER  
ø2  
ADJUSTABLE  
ANTENNA  
TURNTABLE  
SWITCHING GLITCHES  
Figure 33. Radiated Emissions Test Setup  
Figure 34 shows a plot of radiated emissions vs. frequency. This  
shows that the levels of emissions are well within specifications  
without the need for any additional shielding or filtering compo-  
nents. The ADM2xxE was operated at maximum baud rates  
and configured as in a typical RS-232 interface.  
Figure 31. Switching Glitches  
80  
70  
60  
50  
Testing for radiated emissions was carried out in a shielded  
anechoic chamber.  
LIMIT  
80  
70  
60  
50  
40  
30  
20  
10  
0
LIMIT  
40  
30  
20  
10  
0.3  
0.6  
1
3
6
18  
30  
LOG FREQUENCY – MHz  
Figure 32. Conducted Emissions Plot  
0
START 30.0 MHz  
STOP 200.0 MHz  
Figure 34. Radiated Emissions Plot  
–13–  
REV. B