ADM1030
asserted low. The behavior of the high limit and
THERM
limit
is as follows:
1. Whenever the temperature measured exceeds the high tem-
perature limit, the
INT
pin is asserted low.
2. If the temperature exceeds the
THERM
limit, the
THERM
output asserts low. This can be used to throttle the CPU
clock. If the
THERM-to-Fan
Enable bit (Bit 7 of THERM
behavior/revision register) is cleared to 0, the fan will not run
full-speed. The
THERM
limit may be programmed at a
lower temperature than the high temperature limit. This
allows the system to run in silent mode, where the CPU can
be throttled while the cooling fan is off. If the temperature
continues to increase, and exceeds the high temperature limit,
an
INT
is generated. Software may then decide whether the
fan should run to cool the CPU. This allows the system to
run in SILENT MODE.
3. If the
THERM-to-Fan
Enable bit is set to 1, the fan will run
full-speed whenever
THERM
is asserted low. In this case,
both throttling and active cooling take place. If the high
temperature limit is programmed to a lower value than the
THERM
limit, exceeding the high temperature limit will
assert
INT
low. Software could change the speed of the fan
depending on temperature readings. If the temperature con-
tinues to increase and exceeds the
THERM
limit,
THERM
asserts low to throttle the CPU and the fan runs full-speed.
This allows the system to run in PERFORMANCE MODE,
where active cooling takes place and the CPU is only throttled
at high temperature.
Using the high temperature limit and the
THERM
limit in this
way allows the user to gain maximum performance from the system
by only slowing it down, should it be at a critical temperature.
Although the ADM1030 does not have a dedicated Interrupt
Mask Register, clearing the appropriate enable bits in Configu-
ration Register 2 will clear the appropriate interrupts and mask
out future interrupts on that channel. Disabling interrupt bits
will prevent out-of-limit conditions from generating an interrupt
or setting a bit in the Status Registers.
USING
THERM
AS AN INPUT
fan is no longer at Alarm Speed. Bit 1 (Fan Fault) is set when-
ever a fan tach failure is detected.
Once cleared, it will reassert on subsequent fan tach failures.
Bits 2 and 3 of Status Register 1 are the Remote Temperature
High and Low status bits. Exceeding the high or low tempera-
ture limits for the external channel sets these status bits. Reading
the status register clears these bits. However, these bits will be
reasserted if the out-of limit condition still exists on the next
monitoring cycle. Bits 6 and 7 are the Local Temperature High
and Low status bits. These behave exactly the same as the Remote
Temperature High and Low status bits. Bit 4 of Status Register
1 indicates that the Remote Temperature THERM limit has
been exceeded. This bit gets cleared on a read of Status Register
1 (see Figure 5). Bit 5 indicates a Remote Diode Error. This
bit will be a 1 if a short or open is detected on the Remote
Temperature channel on power-up. If this bit is set to 1 on
power-up, it cannot be cleared. Bit 6 of Status Register 2 (0x03)
indicates that the Local THERM limit has been exceeded. This bit
is cleared on a read of Status Register 2. Bit 7 indicates that
THERM
has been pulled low as an input. This bit can also be
cleared on a read of Status Register 2.
THERM LIMIT
5
TEMP
THERM
INT
REARMED
INT
STATUS REG. READ
Figure 5. Operation of
THERM
and
INT
Signals
The
THERM
pin is an open-drain input/output pin. When used
as an output, it signals over-temperature conditions. When
asserted low as an output, the fan will be driven full-speed if the
THERM-to-Fan
Enable bit is set to 1 (Bit 7 of Register 0x3F).
When
THERM
is pulled low as an input, the
THERM
bit (Bit
7) of Status Register 2 is set to 1, and the fan is driven full-speed.
Note that the
THERM-to-Fan
Enable bit has no effect when-
ever
THERM
is used as an input. If
THERM
is pulled low as
an input, and the
THERM-to-Fan
Enable bit = 0, the fan will
still be driven full-speed. The
THERM-to-Fan
Enable bit only
affects the behavior of
THERM
when used as an output.
STATUS REGISTERS
Figure 5 shows the interaction between
INT
and
THERM.
Once a critical temperature THERM limit is exceeded, both
INT
and
THERM
assert low. Reading the Status Registers
clears the interrupt and the
INT
pin goes high. However, the
THERM pin remains asserted until the measured temperature
falls 5°C below the exceeded
THERM
limit. This feature can be
used to CPU throttle or drive a fan full-speed for maximum
cooling. Note, that the
INT
pin for that interrupt source is not
rearmed until the temperature has fallen below the THERM
limit –5°C. This prevents unnecessary interrupts from tying up
valuable CPU resources.
MODES OF OPERATION
The ADM1030 has four different modes of operation. These
modes determine the behavior of the system.
1. Automatic Fan Speed Control Mode.
2. Filtered Automatic Fan Speed Control Mode.
3. PWM Duty Cycle Select Mode (directly sets fan speed under
software control).
4. RPM Feedback Mode.
All out-of-limit conditions are flagged by status bits in Status
Registers 1 and 2 (0x02, 0x03). Bits 0 and 1 (Alarm Speed, Fan
Fault) of Status Register 1, once set, may be cleared by reading
Status Register 1. Once the Alarm Speed bit is cleared, this bit
will not be reasserted on the next monitoring cycle even if the
condition still persists. This bit may be reasserted only if the
REV. 0
–11–