ADM1024  
If the fan has a strong pull-up (less than 1 k) to 12 V, or a  
totem-pole output, then a series resistor can be added to limit the  
Zener current, as shown in Figure 17c. Alternatively, a resistive  
attenuator may be used, as shown in Figure 17d.  
The monitoring cycle begins when a one is written to the Start  
Bit (Bit 0), and a zero to the INT_Clear Bit (Bit 3) of the  
Configuration Register. INT_Enable (Bit 1) should be set to  
one to enable the INT output. The measurement begins on the  
rising edge of a fan tach pulse, and ends on the next-but-one  
rising edge. The fans are monitored sequentially, so if only one  
fan is monitored the monitoring time is the time taken after the  
Start Bit for it to produce two complete tach cycles or for the  
counter to reach full scale, whichever occurs sooner. If more  
than one fan is monitored, the monitoring time depends on the  
speed of the fans and the timing relationship of their tach pulses.  
This is illustrated in Figure 19. Once the fan speeds have been  
measured, they will be stored in the Fan Speed Value Registers  
and the most recent value can be read at any time. The measure-  
ments will be updated as long as the monitoring cycle continues.  
R1 and R2 should be chosen such that:  
2 V < VPULL-UP × R2/(RPULL-UP + R1 + R2) < 5 V  
The fan inputs have an input resistance of nominally 160 kto  
ground, so this should be taken into account when calculating  
resistor values.  
With a pull-up voltage of 12 V and pull-up resistor less than 1 k,  
suitable values for R1 and R2 would be 100 kand 47 k. This  
will give a high-input voltage of 3.83 V.  
V
CC  
12V  
To accommodate fans of different speed and/or different num-  
bers of output pulses per revolution, a prescaler (divisor) of  
1, 2, 4, or 8 may be added before the counter. The default value  
is 2, which gives a count of 153 for a fan running at 4400 rpm  
producing two output pulses per revolution.  
PULL-UP  
TYP. <1k⍀  
OR TOTEM-POLE  
FAN1 OR  
FAN2  
R1  
10k⍀  
FAN SPEED  
COUNTER  
TACHO  
OUTPUT  
160k⍀  
ZD1*  
ZENER  
The count is calculated by the equation:  
Count = (22.5 × 103 × 60) /(rpm × Divisor)  
*CHOOSE ZD1 VOLTAGE APPROX. 0.8 
؋
 V  
CC  
For constant speed fans, fan failure is normally considered to have  
occurred when the speed drops below 70% of nominal, which  
would correspond to a count of 219. Full scale (255) would be  
reached if the fan speed fell to 60% of its nominal value. For  
temperature-controlled variable speed fans the situation will be  
different.  
Figure 17c. Fan with Strong Tach. Pull-Up to >VCC or  
Totem-Pole Output, Clamped with Zener and Resistor  
12V  
V
CC  
FAN1 OR  
FAN2  
Table V shows the relationship between fan speed and time  
per revolution at 60%, 70%, and 100% of nominal rpm for fan  
speeds of 1100, 2200, 4400, and 8800 rpm, and the divisor that  
would be used for each of these fans, based on two tach pulses  
per revolution.  
<1k  
R1*  
FAN SPEED  
COUNTER  
TACHO  
OUTPUT  
160k⍀  
R2*  
*SEE TEXT  
Figure 17d. Fan with Strong Tach. Pull-Up to >VCC or  
Totem-Pole Output, Attenuated with R1/R2  
Table V. Fan Speeds and Divisors  
Time  
per  
Time  
per  
Time  
per  
FAN SPEED MEASUREMENT  
The fan counter does not count the fan tach output pulses directly,  
because the fan speed may be less than 1000 rpm and it would  
take several seconds to accumulate a reasonably large and accu-  
rate count. Instead, the period of the fan revolution is measured  
by gating an on-chip 22.5 kHz oscillator into the input of an 8-bit  
counter for two periods of the fan tach output, as shown in Fig-  
ure 18; the accumulated count is actually proportional to the fan  
tach period and inversely proportional to the fan speed.  
Nominal Rev  
Divisor rpm  
70% Rev (70%) 60% Rev (60%)  
(ms) rpm (ms)  
rpm (ms)  
÷1  
÷2  
÷4  
÷8  
8800  
4400  
2200  
1100  
6.82 6160 9.74  
5280 11.36  
2640 22.73  
1320 45.44  
13.64 3080 19.48  
27.27 1540 38.96  
54.54 770 77.92  
660  
90.90  
FAN1 and FAN2 Divisors are programmed into Bits 4 to 7 of  
the VID 0–3/Fan Divisor Register.  
22.5kHz  
CLOCK  
LIMIT VALUES  
CONFIG.  
REG.1 BIT 0  
Fans in general will not overspeed if run from the correct voltage,  
so the failure condition of interest is underspeed due to electrical  
or mechanical failure. For this reason only, low-speed limits are  
programmed into the limit registers for the fans. It should be noted  
that, since fan period rather than speed is being measured, a fan  
failure interrupt will occur when the measurement exceeds the  
limit value.  
FAN1  
INPUT  
FAN2  
INPUT  
FAN1  
MEASUREMENT  
PERIOD  
FAN2  
MEASUREMENT  
PERIOD  
MONITORING CYCLE TIME  
START OF  
MONITORING  
CYCLE  
The monitoring cycle time depends on the fan speed and number  
of tach output pulses per revolution. Two complete periods of the  
fan tach output (three rising edges) are required for each fan  
Figure 18. Fan Speed Measurement  
REV. 0  
–16–