ADG711/ADG712/ADG713
TERMINOLOGY
tON
RON
Delay between applying the digital control input and the output
switching on.
Ohmic resistance between D and S.
ΔRON
tOFF
On resistance match between any two channels, ie., RONmax −
Delay between applying the digital control input and the output
switching off.
RONmin.
RFLAT(ON)
tD
Flatness is defined as the difference between the maximum and
minimum value of on resistance as measured over the specified
analog signal range.
Off time or on time measured between the 90% points of both
switches, when switching from one address state to another
(ADG713 only).
IS (OFF)
Crosstalk
Source leakage current with the switch off.
A measure of unwanted signal that is coupled through from one
channel to another as a result of parasitic capacitance.
ID (OFF)
Drain leakage current with the switch off.
Off Isolation
ID, IS (ON)
A measure of unwanted signal coupling through an off switch.
Channel leakage current with the switch on.
Charge Injection
A measure of the glitch impulse transferred from the digital
input to the analog output during switching.
VD (VS)
Analog voltage on Terminals D, S.
CS (OFF)
Bandwidth
Off switch source capacitance.
The frequency at which the output is attenuated by 3 dB.
CD (OFF)
On Response
Off switch drain capacitance.
The frequency response of the on switch.
CD, CS (ON)
On switch capacitance.