AD9221/AD9223/AD9220
SWITCHING SPECIFICATIONS
(TMIN to TMAX with AVDD = +5 V, DVDD = +5 V, CL = 20 pF)
Parameters
Symbol
AD9221
AD9223
AD9220
Units
Clock Period1
CLOCK Pulsewidth High
CLOCK Pulsewidth Low
Output Delay
tC
667
300
300
8
333
150
150
8
100
45
45
8
ns min
ns min
ns min
ns min
tCH
tCL
tOD
13
19
3
13
19
3
13
19
3
ns typ
ns max
Clock Cycles
Pipeline Delay (Latency)
NOTES
1The clock period may be extended to 1 ms without degradation in specified performance @ +25°C.
Specifications subject to change without notice.
S1
S2
ANALOG
INPUT
S4
tC
S3
tCH
tCL
INPUT
CLOCK
tOD
DATA
OUTPUT
DATA 1
Figure 1. Timing Diagram
ABSOLUTE MAXIMUM RATINGS*
THERMAL CHARACTERISTICS
Thermal Resistance
28-Lead SOIC
θJA = 71.4°C/W
θJC = 23°C/W
28-Lead SSOP
θJA = 63.3°C/W
θJC = 23°C/W
With
Respect
to
Parameter
Min Max
Units
AVDD
DVDD
AVSS
AVSS
DVSS
DVSS
–0.3 +6.5
–0.3 +6.5
–0.3 +0.3
V
V
V
V
AVDD
DVDD –6.5 +6.5
REFCOM
CLK
Digital Outputs
VINA, VINB
VREF
AVSS
AVSS
DVSS
AVSS
AVSS
AVSS
AVSS
–0.3 +0.3
V
V
V
V
V
V
V
°C
°C
ORDERING GUIDE
–0.3 AVDD + 0.3
–0.3 DVDD + 0.3
–0.3 AVDD + 0.3
–0.3 AVDD + 0.3
–0.3 AVDD + 0.3
–0.3 AVDD + 0.3
+150
Temperature
Range
Package
Description
Package
Options
Model
AD9221AR
AD9223AR
AD9220AR
AD9221ARS
AD9223ARS
AD9220ARS
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
28-Lead SOIC R-28
28-Lead SOIC R-28
28-Lead SOIC R-28
28-Lead SSOP RS-28
28-Lead SSOP RS-28
28-Lead SSOP RS-28
SENSE
CAPB, CAPT
Junction Temperature
Storage Temperature
Lead Temperature
(10 sec)
–65
+150
+300
°C
AD9220/AD9221/AD9223SOICEB Evaluation Board
AD9220/AD9221/AD9223SSOPEB Evaluation Board
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum
ratings for extended periods may effect device reliability.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although these devices feature proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–4–
REV. D