AD8057/AD8058
ABSOLUTE MAXIMUM RATINGS
1
MAXIMUM POWER DISSIPATION
Supply Voltage (+V
S
to –V
S
) . . . . . . . . . . . . . . . . . . . . . 12.6 V
Internal Power Dissipation
2
SOIC Package (R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.8 W
SOT-23-5 Package (RT) . . . . . . . . . . . . . . . . . . . . . . . 0.5 W
MSOP Package (RM) . . . . . . . . . . . . . . . . . . . . . . . . . 0.6 W
Input Voltage (Common Mode) . . . . . . . . . . . . . . . . . . . .
±
V
S
Differential Input Voltage . . . . . . . . . . . . . . . . . . . . . . .
±
4.0 V
Output Short Circuit Duration
. . . . . . . . . . . . . . . . . . Observe Power Derating Curves
Storage Temperature Range (R) . . . . . . . . . –65°C to +125°C
Operating Temperature Range (A Grade) . . . –40°C to +85°C
Lead Temperature Range (Soldering 10 sec) . . . . . . . . . 300°C
NOTES
1
Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
2
Specification is for device in free air:
8-Lead SOIC Package:
JA
= 160°C/W
5-Lead SOT-23-5 Package:
JA
= 240°C/W
8-Lead MSOP Package:
JA
= 200°C/W
The maximum power that can be safely dissipated by the
AD8057/AD8058 is limited by the associated rise in junction
temperature. Exceeding a junction temperature of 175°C for an
extended period can result in device failure. While the AD8057/
AD8058 is internally short-circuit protected, this may not be
sufficient to guarantee that the maximum junction temperature
(150°C) is not exceeded under all conditions.
To ensure proper operation, it is necessary to observe the maxi-
mum power derating curves.
2.0
T
J
= 150 C
MAXIMUM POWER DISSIPATION (W)
1.5
8-LEAD SOIC
1.0
8-LEAD MSOP
0.5
SOT-23-5
0
–50 –40 –30 –20 –10 0 10 20 30 40 50 60
AMBIENT TEMPERATURE ( C)
70
80
90
Figure 2. Plot of Maximum Power Dissipation vs.
Temperature
ORDERING GUIDE
Model
AD8057AR
AD8057ACHIPS
AD8057AR-REEL
AD8057AR-REEL7
AD8057ART-R2
AD8057ART-REEL
AD8057ART-REEL7
AD8057ARTZ-REEL7*
AD8058AR
AD8058ACHIPS
AD8058AR-REEL
AD8058AR-REEL7
AD8058ARZ-REEL7*
AD8058ARM
AD8058ARM-REEL
AD8058ARM-REEL7
AD8058ARMZ-REEL7*
*Lead
free
Temperature Range
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
Package Description
8-Lead Narrow Body SOIC
Die
8-Lead SOIC, 13" Reel
8-Lead SOIC, 7" Reel
5-Lead SOT-23
5-Lead SOT-23, 13" Reel
5-Lead SOT-23, 7" Reel
5-Lead SOT-23, 7" Reel
8-Lead Narrow Body SOIC
Die
8-Lead SOIC, 13" Reel
8-Lead SOIC, 7" Reel
8-Lead SOIC, 7" Reel
8-Lead MSOP
8-Lead MSOP, 13" Reel
8-Lead MSOP, 7" Reel
8-Lead MSOP, 7" Reel
Package Option
R-8
Waffle Pak
R-8
R-8
RT-5
RT-5
RT-5
RT-5
R-8
Waffle Pak
R-8
R-8
R-8
RM-8
RM-8
RM-8
RM-8
Branding
Standard
N/A
Standard
Standard
H7A
H7A
H7A
H7A
Standard
N/A
Standard
Standard
Standard
H8A
H8A
H8A
H8A
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD8057/AD8058 features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
–4–
REV. B