AD795
Parameter
POWER SUPPLY
Rated Performance
Operating Range
Quiescent Current
1
2
Test Conditions/Comments
Min
AD795JR
Typ
±15
Max
Unit
V
V
mA
±4
1.3
±18
1.5
Input offset voltage specifications are guaranteed after 5 minutes of operation at T
A
= +25°C.
Bias current specifications are guaranteed maximum at either input after 5 minutes of operation at T
A
= +25°C. For higher temperature, the current doubles every 10°C.
3
Gain = −1, R1 = 10 kΩ.
4
Defined as the time required for the amplifier’s output to return to normal operation after removal of a 50% overload from the amplifier input.
5
Defined as the maximum continuous voltage between the inputs such that neither input exceeds ±10 V from ground.
Rev. C | Page 4 of 20