AD7705/AD7706  
CONFIGURING THE AD7705/AD7706  
the DRDY pin is polled to determine when an update of the  
data register has taken place, the second where the DRDY bit of  
the Communications Register is interrogated to see if a data  
register update has taken place. Also included in the flowing dia-  
gram is a series of words that should be written to the registers  
for a particular set of operating conditions. These conditions  
are gain of one, no filter sync, bipolar mode, buffer off, clock of  
4.9512 MHz and an output rate of 50 Hz.  
The AD7705/AD7706 contains six on-chip registers that the  
user can accesses via the serial interface. Communication with  
any of these registers is initiated by writing to the Communica-  
tions Register first. Figure 18 outlines a flow diagram of the  
sequence used to configure all registers after a power-up or reset  
on the AD7705, similar procedures apply to the AD7706. The  
flowchart also shows two different read options—the first where  
START  
POWER-ON/RESET FOR AD7705  
CONFIGURE & INITIALIZE C/P SERIAL PORT  
WRITE TO COMMUNICATIONS REGISTER SELECTING  
CHANNEL & SETTING UP NEXT OPERATION TO BE A  
WRITE TO THE CLOCK REGISTER (20 HEX)  
WRITE TO CLOCK REGISTER SETTING THE CLOCK  
BITS IN ACCORDANCE WITH THE APPLIED MASTER  
CLOCK SIGNAL AND SELECT UPDATE RATE FOR  
SELECTED CHANNEL (0C HEX)  
WRITE TO COMMUNICATIONS REGISTER SELECTING  
CHANNEL & SETTING UP NEXT OPERATION TO BE A  
WRITE TO THE SETUP REGISTER (10 HEX)  
WRITE TO SETUP REGISTER CLEARING F SYNC,  
SETTING UP GAIN, OPERATING CONDITIONS &  
INITIATING A SELF-CALIBRATION ON SELECTED  
CHANNEL (40 HEX)  
POLL DRDY PIN  
NO  
WRITE TO COMMUNICATIONS REGISTER SETTING UP NEXT  
OPERATION TO BE A READ FROM THE COMMUNICATIONS  
REGISTER (08 HEX)  
DRDY  
LOW?  
YES  
READ FROM COMMUNICATIONS REGISTER  
WRITE TO COMMUNICATIONS REGISTER SETTING UP  
NEXT OPERATION TO BE A READ FROM THE DATA  
REGISTER (38 HEX)  
POLL DRDY BIT OF COMMUNICATIONS REGISTER  
READ FROM DATA REGISTER  
NO  
DRDY  
LOW?  
YES  
WRITE TO COMMUNICATIONS REGISTER SETTING UP  
NEXT OPERATION TO BE A READ FROM THE DATA  
REGISTER (38 HEX)  
READ FROM DATA REGISTER  
Figure 18. Flowchart for Setting Up and Reading from the AD7705  
–25–  
REV. A  