Low Cost Low Power
Instrumentation Amplifier
AD620
FEATURES
Easy to use
Gain set with one external resistor
(Gain range 1 to 10,000)
Wide power supply range (±2.3 V to ±18 V)
Higher performance than 3 op amp IA designs
Available in 8-lead DIP and SOIC packaging
Low power, 1.3 mA max supply current
Excellent dc performance (B grade)
50 µV max, input offset voltage
0.6 µV/°C max, input offset drift
1.0 nA max, input bias current
100 dB min common-mode rejection ratio (G = 10)
Low noise
9 nV/√Hz @ 1 kHz, input voltage noise
0.28 µV p-p noise (0.1 Hz to 10 Hz)
Excellent ac specifications
120 kHz bandwidth (G = 100)
15 µs settling time to 0.01%
CONNECTION DIAGRAM
R
G
–IN
+IN
–V
S
1
2
3
4
8
R
G
7 +V
S
6
OUTPUT
00775-0-001
AD620
TOP VIEW
5 REF
Figure 1. 8-Lead PDIP (N), CERDIP (Q), and SOIC (R) Packages
PRODUCT DESCRIPTION
The AD620 is a low cost, high accuracy instrumentation
amplifier that requires only one external resistor to set gains of
1 to 10,000. Furthermore, the AD620 features 8-lead SOIC and
DIP packaging that is smaller than discrete designs and offers
lower power (only 1.3 mA max supply current), making it a
good fit for battery-powered, portable (or remote) applications.
The AD620, with its high accuracy of 40 ppm maximum
nonlinearity, low offset voltage of 50 µV max, and offset drift of
0.6 µV/°C max, is ideal for use in precision data acquisition
systems, such as weigh scales and transducer interfaces.
Furthermore, the low noise, low input bias current, and low power
of the AD620 make it well suited for medical applications, such
as ECG and noninvasive blood pressure monitors.
The low input bias current of 1.0 nA max is made possible with
the use of Superϐeta processing in the input stage. The AD620
works well as a preamplifier due to its low input voltage noise of
9 nV/√Hz at 1 kHz, 0.28 µV p-p in the 0.1 Hz to 10 Hz band,
and 0.1 pA/√Hz input current noise. Also, the AD620 is well
suited for multiplexed applications with its settling time of 15 µs
to 0.01%, and its cost is low enough to enable designs with one
in-amp per channel.
10,000
APPLICATIONS
Weigh scales
ECG and medical instrumentation
Transducer interface
Data acquisition systems
Industrial process controls
Battery-powered and portable equipment
30,000
TOTAL ERROR, PPM OF FULL SCALE
25,000
3 OP AMP
IN-AMP
(3 OP-07s)
1,000
20,000
RTI VOLTAGE NOISE
(0.1 – 10Hz) (
µ
V p-p)
TYPICAL STANDARD
BIPOLAR INPUT
IN-AMP
100
G = 100
10
AD620 SUPER
β
ETA
BIPOLAR INPUT
IN-AMP
15,000
AD620A
10,000
R
G
5,000
00775-0-002
1
0
0
5
10
SUPPLY CURRENT (mA)
15
20
0.1
1k
10k
100k
1M
SOURCE RESISTANCE (
)
10M
100M
Figure 2. Three Op Amp IA Designs vs. AD620
Rev. G
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective owners.
Figure 3. Total Voltage Noise vs. Source Resistance
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.326.8703
© 2004 Analog Devices, Inc. All rights reserved.