AD590–SPECIFICATIONS
(@ +25 C and V = +5 V unless otherwise noted)
S
Model
ABSOLUTE MAXIMUM RATINGS
Forward Voltage ( E+ or E–)
Reverse Voltage (E+ to E–)
Breakdown Voltage (Case E+ or E–)
Rated Performance Temperature Range
1
Storage Temperature Range
1
Lead Temperature (Soldering, 10 sec)
POWER SUPPLY
Operating Voltage Range
OUTPUT
Nominal Current Output @ +25°C (298.2K)
Nominal Temperature Coefficient
Calibration Error @ +25°C
Absolute Error (Over Rated Performance Temperature Range)
Without External Calibration Adjustment
With +25°C Calibration Error Set to Zero
Nonlinearity
Repeatability
2
Long-Term Drift
3
Current Noise
Power Supply Rejection
+4 V
≤
V
S
≤
+5 V
+5 V
≤
V
S
≤
+15 V
+15 V
≤
V
S
≤
+30 V
Case Isolation to Either Lead
Effective Shunt Capacitance
Electrical Turn-On Time
Reverse Bias Leakage Current
4
(Reverse Voltage = 10 V)
PACKAGE OPTIONS
TO-52 (H-03A)
Flatpack (F-2A)
AD590J
Min Typ Max
+44
–20
±
200
+150
+155
+300
+30
298.2
1
5.0
10
3.0
1.5
±
0.1
±
0.1
40
0.5
0.2
0.1
10
10
100
20
10
AD590JH
AD590JF
AD590K
Min Typ Max
+44
–20
±
200
+150
+155
+300
+30
298.2
1
2.5
5.5
2.0
0.8
±
0.1
±
0.1
40
0.5
0.2
0.1
10
10
100
20
10
AD590KH
AD590KF
Units
Volts
Volts
Volts
°C
°C
°C
Volts
µA
µA/K
°C
°C
°C
°C
°C
°C
pA/√Hz
µA/V
µV/V
µA/V
Ω
pF
µs
pA
–55
–65
–55
–65
+4
+4
NOTES
1
The AD590 has been used at –100°C and +200°C for short periods of measurement with no physical damage to the device. However, the absolute errors
specified apply to only the rated performance temperature range.
2
Maximum deviation between +25°C readings after temperature cycling between –55°C and +150°C; guaranteed not tested.
3
Conditions: constant +5 V, constant +125°C; guaranteed, not tested.
4
Leakage current doubles every 10°C.
Specifications subject to change without notice.
Specifications shown in
boldface
are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels.
All min and max specifications are guaranteed, although only those shown in
boldface
are tested on all production units.
–2–