AD586
AD586M, AD586S, AD586T
@ TA = 25°C, VIN = 15 V, unless otherwise noted. Specifications in boldface are tested on all production units at final electrical test. Results
from those tests are used to calculate outgoing quality levels. All minimum and maximum specifications are guaranteed, although only
those shown in boldface are tested on all production units, unless otherwise specified.
Table 2.
AD586M
Typ
AD586S
Typ
AD586T
Typ
Parameter
Min
Max
Min
Max
Min
Max
Unit
OUTPUT VOLTAGE
4.998
5.002
4.990
5.010
4.9975
5.0025
V
OUTPUT VOLTAGE
DRIFT1
0°C to 70°C
−55°C to +125°C
GAIN ADJUSTMENT
2
ppm/°C
ppm/°C
%
20
10
+6
+6
+6
−2
−2
−2
%
LINE REGULATION1
10.8 V < +VIN < 36 V
TMIN to TMAX
11.4 V < +VIN < 36 V
TMIN to TMAX
100
µV/V
µV/V
150
150
LOAD REGULATION1
Sourcing 0 mA < IOUT < 10 mA
25°C
100
100
150
150
150
150
µV/mA
µV/mA
TMIN to TMAX
Sinking −10 mA < IOUT < 0 mA
25°C
400
3
400
3
400
3
µV/mA
mA
QUIESCENT CURRENT
POWER CONSUMPTION
OUTPUT NOISE
2
2
2
30
30
30
mW
0.1 Hz to 10 Hz
4
4
4
µV p-p
Spectral Density,
100 Hz
100
100
100
nV/√Hz
LONG-TERM STABILITY
15
45
15
45
15
45
ppm/1000 hr
mA
SHORT-CIRCUIT
CURRENT-TO-GROUND
60
60
60
TEMPERATURE RANGE
Specified Performance2
Operating Performance3
0
−40
70
+85
−55
−55
+125
+125
−55
−55
+125
+125
°C
°C
1 Maximum output voltage drift is guaranteed for all packages and grades. CERDIP packaged parts are also 100°C production tested.
2 Lower row shows specified performance for A and B grades.
3 The operating temperature range is defined as the temperature extremes at which the device will still function. Parts may deviate from their specified performance
outside their specified temperature range.
Rev. G | Page 4 of 16