AD571–SPECIFICATIONS
Model
RESOLUTION
RELATIVE ACCURACY, T
A
T
MIN
to T
MAX
FULL-SCALE CALIBRATION
UNIPOLAR OFFSET
BIPOLAR OFFSET
DIFFERENTIAL NONLINEAIRTY, T
A
T
MIN
to T
MAX
TEMPERATURE RANGE
TEMPERATURE COEFFICIENTS
Unipolar Offset
Bipolar Offset
Full-Scale Calibration
2
POWER SUPPLY REJECTION
CMOS Positive Supply
+13.5 V
≤
V +
≤
+16.5 V
TTL Positive Supply
+4.5 V
≤
V +
≤
+5.5 V
Negative Supply
–16.0 V
≤
V –
≤
–13.5 V
ANALOG INPUT IMPEDANCE
ANALOG INPUT RANGES
Unipolar
Bipolar
OUTPUT CODING
Unipolar
Bipolar
LOGIC OUTPUT
Output Sink Current
(V
OUT
= 0.4 V max, T
MIN
to T
MAX
)
Output Source Current
1
(V
OUT
= 2.4 V max, T
MIN
to T
MAX
)
Output Leakage
LOGIC INPUT
Input Current
Logic “1”
Logic “0”
CONVERSION TIME, T
MIN
to T
MAX
POWER SUPPLY
V+
V–
OPERATING CURRENT
V+
V–
PACKAGE OPTION
2
Ceramic DIP (D-18)
10
9
0
±
2
Min
(T
A
= +25 C, V+ = +5 V, V– = –12 V or –15 V, all voltages measured with respect to
digital common, unless otherwise noted)
Max
10
1
1
±
2
1
1
10
10
+70
2
2
4
0
+70
1
1
2
1/2
1/2
10
10
–55
+125
2
2
5
Min
AD571K
Typ
Max
10
1/2
1/2
±
2
1
1
Min
AD571S
Typ
Max
10
1
1
Units
Bits
LSB
LSB
LSB
LSB
LSB
Bits
Bits
°C
LSB
LSB
LSB
AD571J
Typ
–
–
–
2
2
1
1
1
3.0
0
–5
5.0
7.0
+10
+5
–
–
–
2
2
LSB
LSB
LSB
kΩ
V
V
3.0
0
–5
5.0
7.0
+10
+5
3.0
0
–5
5.0
7.0
+10
+5
Positive True Binary
Positive True Offset Binary
Positive True Binary
Positive True Offset Binary
Positive True Binary
Positive True Offset Binary
3.2
0.5
40
100
2.0
0.8
15
+4.5
–12.0
25
+5.0
–15
7
9
AD571JD
40
+7.0
–16.5
10
15
3.2
0.5
40
100
2.0
0.8
15
+4.5
–12.0
25
+5.0
–15
7
9
40
+16.5
–16.5
10
15
3.2
0.5
40
100
2.0
0.8
15
+4.5
–12.0
25
+5.0
–15
7
9
AD571SD
40
+7.0
–16.5
10
15
mA
mA
µA
µA
V
V
µs
V
V
mA
mA
AD571KD
NOTES
1
The data output lines have active pull-ups to source 0.5 mA. The
DATA READY
line is open collector with a nominal 6 kΩ internal pull-up resistor.
2
For details on grade and package offerings for SD-grade in accordance with MIL-STD-883, refer to Analog Devices’ Military Products databook or current /883B
data sheet.
Specifications subject to change without notice.
Specifications shown in
boldface
are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All min
and max specifications are guaranteed, although only those shown in
boldface
are tested on all production units.
–2–
REV. A