7B14
Nonlinearity2
Refer to Model Table
±1 µV/°C
Input Offset vs. Temperature
Zero Suppression vs. Temperature
Span vs. Temperature
±0.002% (Rz/Rspan)3/°C
±60 ppm/°C
Output Offset vs. Temperature
Lead Resistance Effect
±0.002% Span/°C
±0.02°C/Ω
Output Noise
5 MHz Bandwidth
1 mV peak
0.4 mV rms
0.6 µV peak
3 Hz
10 Hz to 100 Hz Bandwidth
0.1 Hz to 10 Hz Bandwidth
Bandwidth, -3 dB
Output Rise Time
250 ms
Normal Mode Rejection @ 50/60 Hz
Input Protection
60 dB
±30 V dc, continuous
Input Transient Protection
ANSI/IEEE C376.90.1-1989
IEEE-STD 472
IEC 255-4, Class II
Output Resistance
< 1 Ω
Voltage Output Protection
Continuous Short to Ground
Power Supply
Voltage Range, Operating
Current
+14 V dc to +35 V dc
+25 mA, maximum
±0.0001%/% of Vs
Sensitivity
Mechanical Dimensions
1.663" x 2.11" x 0.563"
(42.24 mm x 53.6 mm x 14.3 mm)
Environmental
Temperature Range
Operating
-40°C to +85°C
Storage
-40°C to +85°C
Relative Humidity, 24 hours
ESD Sensitivity
RFI Susceptibility
0 to 90% @ +60°C noncondensing
IEC 801-2, Level 2
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft
Warm-up time required to meet specifications is approximately 10 minutes.
* Contact factory for OEM requirements.
1 Includes the combined effects of repeatability, hysteresis, and nonlinearity.
2 Nonlinearity is calculated using best-fit straight line method.
3 Rz is the value of the RTD resistance at the lowest measurement point. Rspan is the change in resistance over the measurement span.
Specifications subject to change without notice.
Rev. 0 | Page 4 of 8