5B38
Bandwidth, -3 dB
10 kHz
40 µs
*
Output Rise Time, 10% to 90% Span
Output Settling Time, to 0.1%
*
250 µs
7 ms
Common-Mode Voltage (CMV)
Input-to-Output, Continuous
Output-to-Power, Continuous2
Transient
1500 V rms, maximum
±3 V, maximum
*
*
*
ANSI/IEEE C37.90.1-1989
Common-Mode Rejection (CMR)
100 dB
*
*
1 kΩ Source Imbalance, 50/60 Hz
Normal Mode Rejection, 50/60 Hz
-3 dB @ 10 kHz
Input Protection, Signal and Excitation Voltage
240 V rms maximum
ANSI/IEEE C37.90.1-1989
50 Ω
Continuous
*
*
*
*
*
Transient
Output Resistance
Voltage Output Protection
Output Selection Time
Continuous Short to Ground
6 µs @ Cload = 0 to 2,000 pF
Output Enable Control
+1 V
Max Logic "0"
*
*
*
*
*
*
*
*
Min Logic "1"
+2.5 V
Max Logic "1"
+36 V
Input Current "0"
0.4 mA
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
Mechanical Dimensions
+5 V ±5%
200 mA, Full Load; 120 mA, No Load
25 ppm reading/% ±2.5µV RTI/%
2.275" x 2.375" x 0.595"
(57.8 mm x 59.1 mm x 15.1 mm)
Environmental
Temperature Range
Rated Performance
Operating
-25°C to +85°C
*
*
*
*
*
-40°C to +85°C
Storage
-40°C to +85°C
Relative Humidity
RFI Susceptibility
* Same as full-bridge version.
0 to 93% @ +40°C non-condensing
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft
1 Includes the combined effects of repeatability, hysteresis, and nonlinearity. Loads heavier than
50 kΩ will degrade nonlinearity and gain temperature coefficient.
2 The output common must be kept within ±3 V of power common.
Specifications subject to change without notice.
Rev. 0 | Page 4 of 8